5 OPERATION
0463 605 001
- 19 -
© ESAB AB 2018
5.5.3
GTAW (TIG) 400 V
V = Output voltage
A = Welding current (Amps)
5.6
Duty cycle
The EMP 255ic has a welding current output of 255 A at 40% duty cycle. The EMP 320 has a
welding current output of 320 A at 40% duty cycle. A self-resetting thermostat will protect the
power source if the duty cycle is exceeded.
Example:
If the power source operates at a 40% duty cycle, it will provide the rated
amperage for a maximum of 4 minutes out of every 10-minute period. The remaining time, 6
minutes, the power source must be allowed to cool down with fans running.
A different combination of duty cycle and welding current can be selected. Use the graphs
below to determine the correct duty cycle for a given welding current.