ESAB CUTMASTER 80
SERVICE
Manual 0-5396
5-4
5.05 Basic Troubleshooting Guide
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do
not attempt to diagnose or repair unless you have had training in power electronics
measurement and troubleshooting techniques.
Problem - Symptom Possible Cause
Recommended Action
ON / OFF Switch
is ON but the A/C
Indicator does not
light
1. Primary power disconnect is in
OFF position.
2. Primary fuses / breakers are
blown or tripped.
3. Units internal fuse blown.
4. Faulty components in unit.
1. Turn primary power disconnect switch to ON position.
2. a) Have qualified person check primary fuses / breakers.
b) Connect unit to known good primary power receptacle
3. a) Replace fuse.
b) If fuse blows again, return to authorized service center for
repair or replacement.
4. Return to authorized service center for repair or replacement.
Fault indicator
flashing, 65 PSI
indicator flashing
1. Improper input voltage.
2. Primary input voltage problem.
3. Faulty components in unit.
1. Check for proper primary input voltage.
2. Have qualified person check primary voltage to insure it meets
unit requirements see section 2.05.
3. Return to authorized service center for repair or replacement.
TEMPERATURE
indicator ON. FAULT
indicator flashing.
1. Air flow through or around the unit
is obstructed.
2. Duty cycle of the unit has been
exceeded
3. Failed components in unit
1. Refer to clearance information – section 2.04
2. Allow unit to cool.
3. Return to authorized service center for repair or replacement.
GAS LED OFF,
FAULT and MIN
pressure indicators
flashing.
1. Gas supply not connected to unit.
2. Gas supply not turned ON.
3. Gas supply pressure too low.
4. AIR PRESSURE CONTROL
regulator set too low.
5. Failed components in unit.
1. Connect gas supply to unit.
2. Turn gas supply ON.
3. Set air supply inlet pressure to unit to 120 psi.
4. Adjust regulator to set air pressure - see section 4.02.
5. Return to authorized service center for repair or replacement.
FAULT and 70 PSI
indicators flashing.
1. Shield Cup loose.
2. Torch not properly connected to
power supply.
3. Problem in torch and leads PIP
circuit.
4. Failed components in unit.
1. Hand tighten the shield cup until it is snug.
2. Insure torch ATC is securely fastened to unit.
3. Replace torch and leads or return to authorized service center
for repair or replacement.
4. Return to authorized service center for repair or replacement.
FAULT and 75 PSI
indicators flashing.
1. Start signal is active when ON/
OFF SWITCH is turned to ON
position.
2. Problem in the torch and leads
switch circuit.
3. Failed components in unit.
1. Start can be active for one of the following:
• Hand torch switch held closed
• Hand pendant switch held closed
• CNC START signal is active low
Release the START signal source
2. Replace torch and leads or return to authorized service center
for repair or replacement.
3. Return to authorized service center for repair or replacement.
Содержание Cutmaster 40 SL60 1Torch
Страница 9: ...This Page Intentionally Blank ...
Страница 56: ...ESAB CUTMASTER 80 Manual 0 5396 GENERAL INFORMATION This page intentionally blank ...
Страница 64: ...ESAB CUTMASTER 80 INTRODUCTION Manual 0 5396 2T 4 This Page Intentionally Blank ...
Страница 68: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3 4 This Page Intentionally Blank ...
Страница 70: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3T 2 This Page Intentionally Blank ...
Страница 74: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4 4 This Page Intentionally Blank ...
Страница 89: ...ESAB CUTMASTER 80 Manual 0 5396 OPERATION 4T 15 This Page Intentionally Blank ...
Страница 92: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4T 18 This Page Intentionally Blank ...
Страница 107: ...ESAB CUTMASTER 80 Manual 0 5396 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 115: ...ESAB CUTMASTER 80 Manual 0 5396 APPENDIX A 5 This Page Intentionally Blank ...
Страница 118: ...ESAB CUTMASTER 80 APPENDIX Manual 0 5396 A 8 Revision History Date Rev Description 01 15 2015 AA Manual release ...
Страница 119: ...This Page Intentionally Blank ...