ESAB CUTMASTER 80
INTRODUCTION
Manual 0-5396
2T-2
F. Torch Ratings
Manual Torch Ratings
Ambient
Temperature
104° F
40° C
Duty Cycle
100% @ 60 Amps @ 400 scfh
Maximum Current
80 Amps
Voltage (V
peak
)
500V
Arc Striking Voltage
7kV
Mechanized Torch Ratings
Ambient
Temperature
104° F
40° C
Duty Cycle
100% @ 100 Amps @ 400 scfh
Maximum Current
120 Amps
Voltage (V
peak
)
500V
Arc Striking Voltage
7kV
G. Gas Requirements
Manual and Mechanized Torch Gas
Specifications
Gas (Plasma and Secondary)
Compressed Air
Operating Pressure
Refer to NOTE
60 - 95 psi
4.1 - 6.5 bar
Maximum Input Pressure
125 psi / 8.6 bar
Gas Flow (Cutting and
Gouging)
300 - 500 scfh
142 - 235 lpm
!
WARNING
This torch is not to be used with
oxygen (O
2
)
NOTE!
Operating pressure varies with torch
model, operating amperage, and
torch leads length. Refer to gas
pressure settings charts for each
model.
H. Direct Contact Hazard
For standoff tip the recommended standoff is 3/16
inches / 4.7 mm.
2T.04 Options And Accessories
For options and accessories, see section 6.
2T.05 Introduction to Plasma
A. Plasma Gas Flow
Plasma is a gas which has been heated to an
extremely high temperature and ionized so that it
becomes electrically conductive. The plasma arc
cutting and gouging processes use this plasma to
transfer an electrical arc to the workpiece. The metal
to be cut or removed is melted by the heat of the arc
and then blown away.
While the goal of plasma arc cutting is separation of
the material, plasma arc gouging is used to remove
metals to a controlled depth and width.
In a Plasma Cutting Torch a cool gas enters Zone B,
where a pilot arc between the electrode and the torch
tip heats and ionizes the gas. The main cutting arc
then transfers to the workpiece through the column
of plasma gas in Zone C.
A-00002
Workpiece
Power
Supply
+
_
C
B
A
Typical Torch Head Detail
By forcing the plasma gas and electric arc through a
small orifice, the torch delivers a high concentration
of heat to a small area. The stiff, constricted plasma
arc is shown in Zone C. Direct current (DC) straight
polarity is used for plasma cutting, as shown in the
illustration.
Zone A channels a secondary gas that cools the
torch. This gas also assists the high velocity plasma
gas in blowing the molten metal out of the cut allow-
ing for a fast, slag - free cut.
Содержание Cutmaster 40 SL60 1Torch
Страница 9: ...This Page Intentionally Blank ...
Страница 56: ...ESAB CUTMASTER 80 Manual 0 5396 GENERAL INFORMATION This page intentionally blank ...
Страница 64: ...ESAB CUTMASTER 80 INTRODUCTION Manual 0 5396 2T 4 This Page Intentionally Blank ...
Страница 68: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3 4 This Page Intentionally Blank ...
Страница 70: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3T 2 This Page Intentionally Blank ...
Страница 74: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4 4 This Page Intentionally Blank ...
Страница 89: ...ESAB CUTMASTER 80 Manual 0 5396 OPERATION 4T 15 This Page Intentionally Blank ...
Страница 92: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4T 18 This Page Intentionally Blank ...
Страница 107: ...ESAB CUTMASTER 80 Manual 0 5396 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 115: ...ESAB CUTMASTER 80 Manual 0 5396 APPENDIX A 5 This Page Intentionally Blank ...
Страница 118: ...ESAB CUTMASTER 80 APPENDIX Manual 0 5396 A 8 Revision History Date Rev Description 01 15 2015 AA Manual release ...
Страница 119: ...This Page Intentionally Blank ...