Страница 3: ...power supply 13 5 OPERATION 14 5 1 Connections and control devices 14 5 2 Connection of welding and return cable 15 5 3 Key to symbols 15 5 4 Overheating protection 15 6 MAINTENANCE 16 6 1 Welding po...

Страница 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Страница 5: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Страница 6: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Страница 7: ...welding power source is used together with control unit PEK The welding process parameters are regulated via the control unit The power source is part of ESAB s A2 A6 system which means that most of t...

Страница 8: ...31 F Dimensions l w h 865 610 1320 mm 34x24x52 in Weight 330 kg 727 lbs Insulation class H Enclosure class IP23 Application class Duty cycle The duty cycle refers to the time as a percentage of a ten...

Страница 9: ...the short circuit power is greater than or equal to Sscmin at the interface point between the user s supply and the public system It is the responsibility of the installer or user of the equipment to...

Страница 10: ...even or sloping Position the welding power source so that its cooling air inlets and outlets are not obstructed with a distance of at least 250 mm 9 86 all the way around When installing the power sou...

Страница 11: ...Example of welding equipment 1 Welding head 5 Return cable 9 Measurement cable speed 2 Control unit 6 Measurement cable workpiece 10 Motor cable 3 Control cable 7 Workpiece 11 Measurement cable weldin...

Страница 12: ...985 101 12 ESAB AB 2017 4 4 Cable routing Recommended 3 Control cable 5 Return cable 6 Measurement cable workpiece 8 Welding cable For more information regarding cable routing see the CABLE ROUTING RE...

Страница 13: ...ted to the correct mains voltage and that it is protected by the correct fuse rating A protective earth connection must be made in accordance with regulations Rating plate with supply connection data...

Страница 14: ...rement cable workpiece 3 Push button white ON 10 Fuse 4 Push button black OFF 11 Connection red for measurement cable welding head 5 Connection for control unit PEK 12 Connection for return cable 6 Co...

Страница 15: ...l from the power source Fault indication 5 4 Overheating protection The welding power source has overheating protection that operates if the temperature becomes too high When this occurs the welding c...

Страница 16: ...t the welding power source is not clogged with dirt How often and which cleaning methods apply depend on welding process operation time location surrounding environment The power source should be regu...

Страница 17: ...6 MAINTENANCE 0462 985 101 17 ESAB AB 2017 Replacing and cleaning the air filter 1 Release the air filter according to the illustration 2 Clean the filter using soap and water 3 Reinstall the filter...

Страница 18: ...whether the thermal cut outs have tripped a fault code appears on the control module s panel Check the mains power supply fuses The thermal cut out trips frequently Check to see whether the dust filt...

Страница 19: ...standards IEC EN 60974 1 and IEC EN 60974 10 It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to the mentioned sta...

Страница 20: ...CABLE ROUTING REQUIREMENTS 0462 985 101 20 ESAB AB 2017 CABLE ROUTING REQUIREMENTS Recommended Recommended...

Страница 21: ...CABLE ROUTING REQUIREMENTS 0462 985 101 21 ESAB AB 2017...

Страница 22: ...CABLE ROUTING REQUIREMENTS 0462 985 101 22 ESAB AB 2017...

Страница 23: ...CABLE ROUTING REQUIREMENTS 0462 985 101 23 ESAB AB 2017...

Страница 24: ...CLEANING 0462 985 101 24 ESAB AB 2017 CLEANING...

Страница 25: ...DIAGRAM 0462 985 101 25 ESAB AB 2017 DIAGRAM...

Страница 26: ...ASSEMBLY INSTRUCTIONS 0462 985 101 26 ESAB AB 2017 ASSEMBLY INSTRUCTIONS...

Страница 27: ...CONNECTION INSTRUCTION 0462 985 101 27 ESAB AB 2017 CONNECTION INSTRUCTION...

Страница 28: ...Welding power source Aristo 1000 AC DC SAW 0740 800 205 Service manual Aristo 1000 AC DC SAW 0459 839 050 Spare parts list Aristo 1000 AC DC SAW 0740 801 030 Installation manual For tandem and paralle...

Страница 29: ...WEAR PARTS 0462 985 101 29 ESAB AB 2017 WEAR PARTS Qty Ordering no Denomination 3 0458 398 003 Dust filter 1 0441 828 003 Air filter...

Страница 30: ...60 503 881 Joint tracking unit GMH 0460 502 881 Control unit for motorised slides PAV 0461 235 880 Welding automat A6 Mastertrac 0449 270 900 Welding head A6 SF F1 SAW 0148 140 880 Flux recovery unit...

Страница 31: ...ACCESSORIES 0462 985 101 31 ESAB AB 2017...

Страница 32: ...Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWI...