ESAB A6 CRE 30 Скачать руководство пользователя страница 1

Valid for serial no. 452--xxx--xxxx

0443 423 001 2001--06--28

A6 CRE 30/

A6 CRE 60

101103105107109111102021110025108024042106023061104022041100020040060001

Bruksanvisning

Brugsanvisning

Bruksanvisning

Käyttöohjeet

Instruction manual

Betriebsanweisung

Manuel d’instructions

Gebruiksaanwijzing

Instrucciones de uso

Istruzioni per l’uso

Manual de instruções

Ïäçãßåò ÷ñÞóåùò

Содержание A6 CRE 30

Страница 1: ...60 101103105107109111102021110025108024042106023061104022041100020040060001 Bruksanvisning Brugsanvisning Bruksanvisning K ytt ohjeet Instruction manual Betriebsanweisung Manuel d instructions Gebruik...

Страница 2: ...erungen vorbehalten Sous r serve de modifications sans avis pr alable Recht op wijzigingen zonder voorafgaande mededeling voorbehouden Reservado el derecho de cambiar las especificaciones sin previo a...

Страница 3: ...nting Placement 56 3 3 Inlet outlet for air 57 4 OPERATION 58 4 1 General 58 4 2 Starting the air drying unit 58 4 3 Functional assessment of air drying unit 59 5 MAINTENANCE 60 5 1 General 60 6 FAULT...

Страница 4: ...S location of emergency stops S its function S relevant safety precautions S welding 2 The operator must ensure that S no unauthorized person is stationed within the working area of the equipment when...

Страница 5: ...ce is safe FUMES AND GASES Can be dangerous to health S Keep your head out of the fumes S Use ventilation extraction at the arc or both to keep fumes and gases from your breathing zone and the general...

Страница 6: ...60 Hz Max power rating 40 W 50 W Net air flow capacity at 6 bar 30 Nm3 h 60 Nm3 h Regenerating flow at 6 bar 14 14 Maximum dew point under nominal working condi tions 26_C 26_C Desiccant 512 Sodium Al...

Страница 7: ...through solenoid valves Y1 and Y2 4 When the left container has been used for a while solenoid valve Y2 closes and pressure begins building up in the right container 5 When the pressure in the two con...

Страница 8: ...e desiccant is destroyed on contact with oil S Install the air drying unit vertical wall mounting Installation dimensions as shown in drawing on page 147 A6 CRE 30 and on page 148 A6 CRE 60 If lifting...

Страница 9: ...nit in question This is important since the performance of the air drying unit depends on the temperature of the inlet air If necessary it is recommended that a cooling radiator is installed before th...

Страница 10: ...on the compressed air NOTE This must be done gradually since a rapid surge of pressure can damage equipment in a compressed air system When full pressure is reached check that there are no leaks at th...

Страница 11: ...er dew point yellow when the drying unit switches from one desiccant container 2 to the other It is therefore advisable to check the indicator at various times during the drying unit cycle before star...

Страница 12: ...rs and that the dew point indicator is working correctly In case of problems the TROUBLESHOOTING section on page 61 may be of help S Check the operation of the dust and oil filters at regular interval...

Страница 13: ...r element Cause 2 2 Flow rate exceeds capacity of drying unit Action Adjust inlet flow 3 Symptom Pressure in regenerator tower Cause 3 1 Filter silencer blocked Action Replace filter silencer Cause 3...

Страница 14: ...through air drying unit Cause 7 1 Compressed air valves leading to or from drying unit are closed also bypass line if fitted Action Open valves 7 ORDERING OF SPARE PARTS Spare parts are ordered throug...

Страница 15: ......

Страница 16: ...LAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax 54 11 4 753 6313 BRAZIL ESAB S A Contagem MG Tel 55 31 333 4...