background image

 

 

www.esabna.com

 

DATE:  January 22, 2004 

BULLETIN NO: M-04-001 

 

 
TITLE/ PRODUCT NAME:  Power Source Faults When Connecting 
 

DuraDrive Wire Feeder 

 
RATING: 

 

_

 

_ DIRECTIVE 

_

X

_ ALERT 

 

 

(Action is Required) 

 

(Potential Problem) 

 
 

 

_

X

_  INFORMATION 

_ _ 

PRODUCT IMPROVEMENT 

 

 

(Action is Optional) 

 

(Enhanced Product) 

 

 

_

X

_ General 

Distribution 

_

 

Business Confidential

 

  

(Unrestricted)   

(Restricted Distribution) 

 

 

 
PRODUCT SERIES/ MODEL:   
 

ESAB 353cv, 453cv and 653cvcc Power Sources 

 

Control Board PN  38129 & 38130  

 

SERIAL NO:   

 

All Serial Numbers 

 

 

SUMMARY:   

 

 

This Instruction will eliminate a nuisance power source fault light when connecting a DuraDrive 
4-30 or 4-48 wire feeder.  The fault condition is caused by a transient voltage spike in the 12 
volt control circuit when power is applied to the DuraDrive feeder.  An additional 22 microfarad 
capacitor is added to increase the time constant of the power up reset circuit which eliminates 
the false triggering of the fault light. 

 

OPERATIONAL IMPACT: 

 

 

None 

 
 
 
 
 