i-CON 1 / 37
3BA00180 • 8.04.008 • Rev. 1
Operating instructions
6.9
Sensitive components
Many components may be damaged by electrostatic discharge (please observe the
warnings on the packaging or ask the manufacturer or supplier). These components
can be protected by an ESD-secure workplace (ESD = electrostatic discharge). The
soldering station can be easily integrated into such an environment. The soldering
tip can be connected at high resistance (220kΩ) to the conductive workbase via the
potential equalization jack (1).
The soldering station has complete antistatic protection and also meets the require-
ments of the American military standard.
The soldering tips are default hard grounded.
*Hard grounded in accordance with military and ESA standard.