6.3.6 Calibration temperature
■
Determine the soldering tip temperature with a calibrated measuring
device (e.g. ERSA DTM 100).
■
Compare the two displayed values of i-CON 1 and the measuring de-
vice.
■
Calculate the temperature difference: ∆T = T
i-CON 1
– T
measuring device
■
Set the calculated temperature difference ∆T (with algebraic sign via
the rotary motion at the i-OP) in the menu item [Calibrate].
Quiet air conditions are important for the prevention of measurement
errors.
6.3.7 Power Level
This function enables the user to influence the regulating behaviour of the station,
whereby the heating and after heating behaviour of the station can be matched to
the actual application. Three settings are possible: [high], [med.] and [low].
• [Low]: Minimum post-heating characteristics. For soldering works with
low heat demand.
• [Med.]: Increased post-heating characteristics. For soldering works with
increased heat demand.
• [High]: Maximum post-heating characteristics. For soldering works with
very high heat demand.