background image

4

IS-C5PERUK Rev. 0 del 5/4/2013

Manufactured by

Via Piave, 23 - I-31020 S.Pietro di Feletto (TV) - ITALY

Tel. 0438.450860 - Fax. 0438.455628

e-mail: [email protected]

Web: www.erone.com

ELPRO INNOTEK S.p.A.

THE SMART LIVING

P1

P1

P1

Keep P1 pressed down for
more 4 sec. until LR3+LV
make 3 long flashes

P1

Keep P1
pressed down
for 2 sec. until
LR1 turns on

Release

P1

LR1

turns on

LR3+LV

3 flashes

GUARANTEE

The guarantee period of this products is 24 months, beginning from the manufacturer date.

During this period, if the product does not work correctly, due to a defective component, the product will be repaired

or substituted at the discretion of the producer.  The guarantee does not cover the plastic enclosure integrity.

After-sale service is supplied at the producer's factory.

DIP-SWITCH 1

Set to ON the switch corresponding to the relay to activate,
i.e.

-->

SW1 = ON, SW2, SW3, SW4 = OFF

ONLY Relay 1 activated.

i.e.

-->

SW1 = ON, SW2 = OFF, SW3 = ON, SW4 = OFF

Relays 1, 3 activated simultaneously

DIP-SWITCH 2

ON

OFF

1 2 3 4

DIP-SWITCH 3

CHANNEL 3 - LED  LR3

( RED )

ON

OFF

1 2 3 4

DIP-SWITCH 4

CHANNEL 4 - LED LV

( GREEN )

ON

OFF

1 2 3 4

DIP5-SWITCH 5

RELAY 5 ( COMMON )

The relay 5 can be activated simultaneously with each relay ( 1,2,3 or 4, depending by the
settings of DIP5.
Set to ON the switch corresponding to the channel which activates simultaneously even the
relay 5.

i.e. : sw1, sw2, sw3, sw4 = OFF : relay 5 NEVER ACTIVATED
i.e. : sw1 = ON, sw2, sw3, sw4 = OFF : relay 5 activated by Channel 1
i.e. : sw1 = ON, sw2 = ON, sw3, sw4 = OFF : relay 5 activated by Channel 1 or
Channel 2

1 2 3 4

1 2 3 4

DIP-SWITCH CONFIGURATION

Each dip-switch sets the relay or the relays activated by the corresponding channel.

ON

OFF

CHANNEL 1 - LED  LR1

( RED )

ON

OFF

CHANNEL 2 - LED LR2

( RED )

FULL MEMORY ERASURE

THE SMART LIVING

1

ERONE  4+1 RELAY RECEIVER SEL2641R433-C5P

INTRODUCTION

The receiver Erone type SEL2641R433-C5P is designed for the control of oleodynamic systems thanks to the 5 output
relays . The main 4 relays gives a C-NO-NC dry contact when the transmission is correctly decoded , the fifth relay can
be activated together to one on them . The memorisation of the transmitter code into the receiver memory can be done
in self-learning mode with one button.

The appliance full complies with the European Directives 89/336/EEC,

73/23/EEC and Regulation EN 60950

TECHNICAL SPECIFICATIONS

Receiver type

Superheterodyne

Local oscillator frequency

6,6128 MHz

Modulation

AM/ASK

Input impedance

50 Ohm

Input sensitivity

-115 dBm

Local oscillator emissions

< -57 dBm

Power supply
Consumption

270 mA

Relays

4 + 1

Relay operating mode

Pulse / Latch

Min applicable power

1A / 6V

User codes max

85

Operating temperature
IP Grade
Weight

400

Overall dimensions (mm )

110 x 110 x 60

Selflearning radio memorisation

yes

Carrier frequency

433.92 MHz

12 / 24 Vdc

Max applicable power

20A / 27V - max 300W

Outputs relays

C - NC - NO

Security protocol

Keeloq hopping code

-20°/+70°C
IP56

gr.

Отзывы: