Orion/3-DN Outdoor
14
2.5
Camera Control Protocol Setting
Define the protocol you are going to use basing on the devices of your
surveillance system. Generally, use one protocol even the devices are
provided from different manufacturers. Please refer to the table below for all
supported protocols with their matching switch numbers and baud rate and
choose a protocol for your Speed Dome Camera.
The table below shows various protocols with their matching switch numbers
and baud rate.
Switch No.
Protocol
Baud Rate
00
VCL
9600
01
Pelco D
2400
02
Pelco P
4800
04
Chiper
9600
05
Philips
9600
06
Ernitec*
2400
07
DSCP
9600
08
AD422
4800
09
DM P
9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2400
14
Pelco P
9600
15
JVC
9600
21
Kalatel-485
9600
22
Kalatel-422
4800
*Only function of Ernitec protocol is fully verified.
Select protocol: Pelco D, with switch no. 01 and baud rate 2400, for instance,
the protocol switch should be set as below.
Decimal Digit Single Digit
NOTE:
The number
“0” should locate upwards as shown in above
diagram for correct switch definition.