NVC/IPE Series
IPE1100 Installation Guide
02A.02
UDP Technology Ltd.
13
Alarm (DO) connection
Only the relay type is supported.
Relay Rating: Max 24VAC 500mA or 12VDC 1A
Caution
!
Do not exceed the maximum relay rating.
Audio connection
EVA 101 has a mono audio input and a mono audio output. As the output power for the audio
is low, amplifier speaker is needed. (Do not use a headphone or earphone directly to the
camera.)
DO
COM
Relay Type
Device
Internal
+5V
DI
COM
DI 1
COM
+
-
Relay Type
Voltage Type
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
Mic
Ain
Speaker
Aout