background image

SSI 1417-S04

PCI-Card with SSI-Out puts

In struc ti on  Manual

Содержание SSI 1417-S04

Страница 1: ...SSI 1417 S04 PCI Card with SSI Outputs Instruction Manual ...

Страница 2: ...he product to ERMA the sender is respon sible for shipping charges freight insurance and proper packaging to prevent breakage in transit ERMA s warranty does not apply to defects resulting from action of thebuyer such mishandling improper interfa cing operation outside of design limits improper repair or unauthorized modification Trademarks Turbo Pascal Delphi are registered trademarks of Borland ...

Страница 3: ... Hardware configuration 7 7 1 1 Component layout 8 7 1 2 Connection of SSI Outputs 9 7 2 Open PC 9 7 3 Card insertion 9 7 4 Close PC 9 7 5 Driver installation 10 7 5 1 Windows 2000 XP 10 8 Programming 10 8 1 Programming under Windows 10 8 2 Programming with S1417S04_DLL DLL 10 8 2 1 Functions 11 8 3 Usage within own applications 13 ERMA Electronic GmbH 2 ...

Страница 4: ...owsCVI 13 8 3 4 C 13 8 3 5 LabView 13 8 4 Direct programming 14 8 4 1 Registers of SSI 1417 15 8 4 2 Tips and Tricks 15 9 Troubleshooting 15 10 Technical datas 16 11 Ordering information 17 3 ERMA Electronic GmbH Stand 03 2010 ssi1417s04_man_en vp Technical subjects to change ...

Страница 5: ...fully No liability will be assumed for any damage caused by improper installation Inspect the instrument module carton for obvious damage Be shure there are no shipping and handling damages on the module before processing Do not apply power to the instrument if it has damaged The warranty does not apply to defects resulting from action of buyer such as mishandling improper interfacing operation ou...

Страница 6: ...ny number of SSI 1417 S04 within one pc depends on number of PCI slots The standard drivers supports up to 4 cards If more than 4 cards should be used you can ask for a driver for more cards The card has one 9 pin SUB D male connector for the inputs and two 9 pin SUB D female connectors for the encoders The functions of the card will be handled in a FPGA This free pro gramable device makes it poss...

Страница 7: ...s advisable To use shielded twisted pair cables The wiring of shields and ground 0V should be star shaped The distance to interference sources should be as far as possible If necessa ry protective screen or metal enclosures must be provided Coils of relays must be supplied with filters Parallel wiring of input signals and AC power lines should be avoided ERMA Electronic GmbH 6 5 Block diagram FPGA...

Страница 8: ...re installation all components have to be disconnected from power supply Because within PC s and the peripherals are high volta ges it is dangerous to life 7 1 Hardware configuration The SSI 1417 S04 uses plug and play and so there is no need for any settings 7 ERMA Electronic GmbH 7 Installation ...

Страница 9: ...7 1 1 Component layout ERMA Electronic GmbH 8 7 Installation male female female SV1 SV2 SV3 SSI0 SSI1 unused component layout ...

Страница 10: ...o the backside of the PC case The slot plate is used for mounting and also for shielding Keep in mind that remo val of the plate will result in loss of shielding and card and PC will be more sensiti ve to EMC Additionaly the card won t be held in slot position when external force will happen to the connected cables Then the card could move within the slot and that can result in damage to the SSI 1...

Страница 11: ...eep the programming of the SSI 1417 S04 as easy as possi ble all functions of the drivers are handled within one DLL So all programming of the card is done by using the DLL The file S1417S04_DLL DLL should be copied to the Windows system directory or the application directory 8 2 Programming with S1417S04_DLL DLL The DLL S1417S04_DLL DLL includes all functions necessary for the work with the SSI 1...

Страница 12: ... This function returns the number of installed SSI 1417 S04 cards S1417S04_GetCardNumber This function returns the serial number of the SSI 1417 S04 card with the desired index Index starts with 0 for the first card S1417S04_GetLastError This function returns the last happened error code Available error codes S1417S04_ERR_OK 0 S1417S04_ERR_ALREADYOPEN 1 S1417S04_ERR_NOTOPEN 2 S1417S04_ERR_NOCARD 3...

Страница 13: ... 1 to max 63 Bit 28 Enable for multiplereading of SSI1 ring register mode Bit 29 Gray Binary Conversion for SSI1 only used in driver softwarefunction Bit 30 31 unused S1417S04_GetConf This function will return the configuration of the card with the desired index Index starts with 0 for the first card The meaning of the bits for the value is the same as for S1417S04_SetConf S1417S04_SetSSI0Value S1...

Страница 14: ...17S04_DLL LIB and a header file S1417S04 H The library has to be inserted in the linker options of the project settings see documentation of VisualC LabWindowsCVI Include the header file in all source files where SSI 1417 S04 functions are needed An additional method is to use the Windows function LoadLibrary to connect the application to the DLL See documentation of VisualC LabWindowsCVI for furt...

Страница 15: ...ion 2 1 The SSI 1417 S04 uses a configuration space header type 00h The datas could be found in the PCI configuration space on BaseAddress0 and BaseAddress1 With BIOS function the data could be read out of the configuration space Ba seAddress0 is used for the PCI target controller BaseAddress1 for the SSI func tions of the card For the BIOS functions the following informations are necessary Vendor...

Страница 16: ... mode Bit 29 unused Bit 30 Global Enable of SSI output registers Bit 31 Global Enable of the card enable output drivers 8 4 2 Tips and Tricks If drivers are developed the following points should be considered While writing to registers set all unused bits to 0 While reading registers mask out all unused bits This will safe compatibility with future changes 9 Troubleshooting All PC boards of ERMA E...

Страница 17: ...ERMA Team The ERMA Team will help you 10 Technical datas Interfaces 2 x SSI outputs Inputs EIA RS422 Max Resolution 32 Bit programable separately for each interface Clock Outputs EIA RS422 Max Clock 5 MHz programmable seperately for each interface Monofloptime 1 µs to 63 µs programmable seperately for each interface Ecoder Power Supply Optional 5 V 2 x 300 mA or 12 V 2 x 125 mA or 24 V 2 x 60 mA I...

Страница 18: ...er Power Supply 0 00 Without power supply 0 05 With 5 V power supply 0 12 With 12 V power supply 0 24 With 24 V power supply Galvanic opto Isolation 0 Without galvanic isolation 1 With galvanic isolation 17 ERMA Electronic GmbH 11 Ordering information ...

Страница 19: ......

Страница 20: ...ERMA Electronic GmbH Max Eyth Str 8 D 78194 Immendingen Telefon 07462 2000 0 Fax 07462 2000 29 email info erma electronic de Web www erma electronic de ...

Отзывы: