![Ericsson ECN320 Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/ericsson/ecn320/ecn320_user-manual_2423381133.webp)
Command Line Interface
1553-CNH 160 0787 Uen PA2 2005-09-23
125
used in a scenario with the EXN104 FE-E1/T1 converter as indicated in
Figure 14 on page 33. The ability to supply a node with power over the
Ethernet cable in the upstream direction can be enabled by the ECN by this
command. It can be disable or set to auto as well.
Command level:
ecn330(config)#.
Syntax
esn <
node
> power-on-uplink {enable|disable|auto}
Arguments:
•
esn <
node
>
– The node number of the ESN108 in the format
a.b
for example 1.0, which refers to the ESN108 connected to port 1 of
the ECN.
•
power-on-uplink enable/disable/auto
– Enable, disable
or automatic configure the ESN108 to supply power over Ethernet
on the uplink connection.
Default Setting
Disabled.
Command Usage
The command is used to enable, disable or automatic configure the
ESN108 to supply power over the Ethernet on the uplink connection.
Example:
ecn330(config)#
esn 3.0 power-on-uplink enable
11.6.6 exn
Table 17
exn commands
Command Description
Page
line
Configure the line properties
packet-distribution
Enable or disable packet distribution
across the parallel E1 links
Содержание ECN320
Страница 1: ...ECN330 and ECN320 User Guide...
Страница 27: ...ECN Functions Features and HW 1553 CNH 160 0787 Uen PA2 2005 09 23 19 Figure 6 Fan Tray...
Страница 60: ...Web interface 52 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 29 Lines Overview...
Страница 62: ...Web interface 54 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 31 Alarm Log...
Страница 173: ...Using a MIB Browser 1553 CNH 160 0787 Uen PA2 2005 09 23 165 Figure 46 Querying VLAN ID...
Страница 187: ......
Страница 188: ...Ericsson AB Ericsson AB 2005 All Rights Reserved www ericsson com 1553 CNH 160 0787 Uen PA2 2005 09 23...