330Wh LiFe battery

ENGLISH

The StyleView LiFe Power Upgrade System is intended to provide AC power to 

support AC powered computer equipment.

This installation manual is only for installation onto an Ergotron cart. For power 

system information, please see provided operations manual.

For the latest User Installation Guide please visit: www.ergotron.com

Содержание StyleView LiFe Power Upgrade System

Страница 1: ...arhandbok svenska ユーザーガイ ド 日本語 用户指南 汉语 StyleView LiFe Power Upgrade System 330Wh LiFe battery ENGLISH The StyleView LiFe Power Upgrade System is intended to provide AC power to support AC powered computer equipment This installation manual is only for installation onto an Ergotron cart For power system information please see provided operations manual For the latest User Installation Guide please ...

Страница 2: ...ion Cart components on riser or tower unless instructed to do so in the installation instructions Moving Cart components too high or too low on the Riser may create an unstable condition leading to equipment damage or even personal injury Contact Ergotron Customer Care for information about moving Cart components WARNING In rare cases if the power system and battery protection features fail the ba...

Страница 3: ... that battery is fully charged 100 1 flashing amber LED indicates that less than 10 of the battery s capacity remains The battery is then ready to be replaced with a charged battery or charged by plugging the power cord into an AC wall outlet CAUTION Do not let battery bump into anything Failure to follow these instructions may cause equipment damage CAUTION Do not move cart while battery is unlat...

Страница 4: ...1x 2x 2x 2 a b c 2x 4x 4x 4x M5 x 10mm 8 32 x 5 8 8 32 x 5 8 8 32 x 3 8 3x 1x 8 32 x 3 8 8 32 x 3 8 1x 1x ENGLISH Components Tools Needed Attach mounting brackets to power module a Remove these four screws from the power module b Attach battery holder to power module ...

Страница 5: ...14 11 3 ENGLISH CART ATTACHMENT OPTIONS Double T slot bracket sold separately Mounting brackets sold separately SV40 SV41 CART NEO FLEX CART CART WITH DUAL T SLOTS ON REAR OF CART SV31 NEO FLEX WIDEVIEW WORKFIT C Attach power module to cart ...

Страница 6: ...6 of 17 888 83 072 G 01 rev D 01 15 4 5 6 180 a b c SV40 SV41 32 813 mm 2x M5 x 10mm ENGLISH ...

Страница 7: ...rev D 01 15 SV40 SV41 9 8 7 a ENGLISH Open worksurface Remove power module cover and plug power and comm cables into BATTERY 1 POWER and COMM ports on the power module Attach SOCI to worksurface as shown for each configuration ...

Страница 8: ...into Replace power module cover Leave enough slack in cable to allow full range of motion Leave enough slack in cable to allow full range of motion WARNING Connecting electrical equipment to the outlet effectively leads to creating a medical system and the result can be a reduced level of safety Route SOCI cable down through bottom of enclosure and plug into power module ...

Страница 9: ...9 of 17 888 83 072 G 01 rev D 01 15 12 SV40 SV41 43 1092 mm b c d a 11 ENGLISH Close worksurface ...

Страница 10: ...ev D 01 15 SV40 SV41 13 14 ENGLISH Attach the coiled power cord to the power module and hang cord on rear handle BATTERY ATTACHMENT REMOVAL Plug coiled cord into wall outlet to charge battery Battery Removal END OF INSTALLATION ...

Страница 11: ...art CAUTION TIPPING HAZARD DO NOT mount off center on either rear corner of cart Doing so will create an unstable situation and may result in personal injury or equipment damage Follow instructions provided with the mounting brackets Attach power module to mounting brackets CARTS WITH DUAL T SLOTS ON REAR OF CART SV31 NEO FLEX WIDEVIEW WORKFIT C ...

Страница 12: ... CARTS WITH DUAL T SLOTS ON REAR OF CART Attach SOCI to worksurface then route cable down and plug into power module Leave enough slack in cable to allow full range of motion Remove power module cover and plug in battery cable Replace power module cover ...

Страница 13: ...strip Attach coiled cord Leave enough slack in cable to allow full range of motion WARNING Connecting electrical equipment to the outlet effectively leads to creating a medical system and the result can be a reduced level of safety Plug coiled cord into wall outlet to charge battery Battery Removal Power strip should be used to plug your equipment into ...

Страница 14: ...EO FLEX NEO FLEX 4 5 32 813 mm 15 25 387 mm 6 ENGLISH Mounting brackets ordered separately Follow instructions provided with the mounting brackets Attach power module to mounting brackets Remove power module cover and plug in battery cable ...

Страница 15: ...allow full range of motion WARNING Connecting electrical equipment to the outlet effectively leads to creating a medical system and the result can be a reduced level of safety Replace power module cover Power strip should be used to plug your equipment into Attach SOCI to worksurface then route cable down and plug into power module Attach power strip ...

Страница 16: ...16 of 17 888 83 072 G 01 rev D 01 15 9 10 NEO FLEX ENGLISH BATTERY ATTACHMENT REMOVAL END OF INSTALLATION Plug coiled cord into wall outlet to charge battery Battery Removal Attach coiled cord ...

Страница 17: ...17 of 17 888 83 072 G 01 rev D 01 15 2015 Ergotron Inc ENGLISH For local customer care phone numbers visit http contact ergotron com NOTE When contacting customer service refer ence the serial number ...