………………..………………………………..….…Maintenance Instructions 6-16
Table 6-16 Material Pump Replacement (continued)
Step
Action
19
Make sure the 1” material port matches the 1” hole in the pump plate; there should
be an alignment pin in the pump plate to insure the correct positioning. Use new
hardware to secure the material pump to the pump plate (6) 3/8”-16 x 5” bolt with (6)
3/8” lock washer. Torque these six bolts at 33 lb-ft.
Note
: Make sure the material pump shaft spins freely after torqueing these bolts.