ergoline ergometrics er 800S Скачать руководство пользователя страница 1

Operation Manual

ergometrics er800S

Art-Nr: 475.051 

!

 

Version:  05/02

Содержание ergometrics er 800S

Страница 1: ...Operation Manual ergometrics er800S Art Nr 475 051 Version 05 02...

Страница 2: ...nufacturer This Operation Manual is not registered for automatic update in case of possible alterations Information regarding the latest version is available from the manufacturer This Operation Manua...

Страница 3: ......

Страница 4: ...Version 05 02 er800S Operation Manual Art No 475 051...

Страница 5: ...trolled Ergometry 10 3 3 Considerations for Control by ECG or PC 11 3 4 Starting the Ergometer 11 3 4 a Starting Automatic Operation 11 3 4 b Starting an ECG or PC Controlled Ergometry 12 3 5 Process...

Страница 6: ...rements 21 5 3 c Setting the Pulse Limit 22 Appendix A Interfaces 23 A 1 Input and Output Pin Specifications 23 Ergometrics er800S RS 232 Interface 24 Appendix B HF Input 27 B 1 HF Return from ECG 27...

Страница 7: ...control and documentation of the training as well as for remote control via an ECG for stress testing It also permits the ergometer to be integrated into a multi station rehab sys tem like ergosoft T...

Страница 8: ...for compre hensive data and documentation services e g ECG units Spirometer PCs etc These in terfaces are supported by the standard software A linear load increment program or a WHO conformant step lo...

Страница 9: ...1 Features and Connections 1 power connector fuse and main power switch 2 clamp handle for seat adjustment 3 clamp handle for handlebar height adjustment 4 clamp handle for handlebar angle adjustment...

Страница 10: ...r heart rate 2 LED display for RPM 3 LED display for power 4 manual power change in 5 Watt steps 3 2 6 1 7 9 5 5 manual power change in 25 Watt steps 6 set base value for start load 7 set value for pu...

Страница 11: ...e of the white outlets at the suction device The ergometer can then be turned on and off by using the main switch on the suction device 1 3 b Attaching a Pulse Meter e g Polar Pacer Connect the Polar...

Страница 12: ...eter Type er800S Chapter 1 Installation 1 3 c Signal Interface Analog interface for analog control and analog data transfer to an ECG Digital RS 232 interface connector for PC or ECG Note Interface pi...

Страница 13: ...Chapter 1 Installation 1 4 Starting the Ergometer Turn on the unit by pressing the main power switch The unit will subsequently execute a self test During this time 888 will be displayed Upon termina...

Страница 14: ...er800S Operation Manual 6 Version 05 02 Art Nr 475 051 Operation Manual Ergometer Type er800S Chapter 1 Installation...

Страница 15: ...og control by an ECG The ergometer can be controlled by an ECG via the analog interface Current data from the ergometer can be requested over this interface external control Training with WHO complian...

Страница 16: ...or will begin to blink with every load change and display the physiologically optimal RPM value expected of the test subject for the established load If this RPM value can be roughly maintained the he...

Страница 17: ...while you adjust the saddle posi tion Saddle height is adjusted by loosening the saddle clamp screw and moving the saddle to the correct position 3 Move the handlebar to a position so that the test s...

Страница 18: ...nual operation of the ergometer 1 Set all parameters to 000 Proceed as described in section 3 2 a and press the red labelled Down key until the value reaches 000 The LED in the correspond ing key will...

Страница 19: ...etrics er800S ergometer can only be controlled by an ECG or a PC if the ECG or the PC supports the interface protocol of the ergometrics er800S Ask your ECG or PC program supplier for details The para...

Страница 20: ...metry See 3 2 a Application of the initial load Po The load program will begin and the initial load Po will be applied Advancing to the second load increment The load will be increased by the programm...

Страница 21: ...c process Terminating the automatic control program by using STOP Press the STOP key as soon as the test subject has started to pedal to freeze the automatic control Ending the ergometry Ergometry wil...

Страница 22: ...Operation Manual Ergometer Type er800S Chapter 3 Ergometric Process er800S Operation Manual 14 Version 05 02 Art Nr 475 051...

Страница 23: ...risk test methods must not be performed by using the bicycle ergometer For such purpose special su pine ergometers are offered by ergoline c Application under outdoor conditions is not permitted d In...

Страница 24: ...gnosis purposes under the supervision of qualified personal ergoline GmbH is only responsible for the safety and reliability of this device if all revisions enhancements repairs and service to the dev...

Страница 25: ...gometrics 800S bicycle ergometer must be regularly inspected and maintained in time intervals of two years in accordance with lawful regulations Alterations to the ergometer s measurement capabilities...

Страница 26: ...Operation Manual Ergometer Type er800S Chapter 4 Safety Maintenance er800S Operation Manual 18 Version 05 02 Art Nr 475 051 4 9 Identification Plate Labelling label with serial number...

Страница 27: ...and load increments may be run or a linear program can be formulated in which the load changes may be pre determined in 5 Watt steps over 1 minute periods Algorithms are selected by simultaneously pr...

Страница 28: ...that the time that a particular load step is run is dependent upon the load change in accordance with the above mentioned values Pulse steady state programs follow an algorithm so that load changes oc...

Страница 29: ...al load setting can only be altered when the ergometer is not actively running a program This means that when a prior ergometric program was run the STOP key must have been pressed after the test subj...

Страница 30: ...the key will blink This value can be altered by using the Up Down keys for as long as the LED continues to blink 5 3 c Setting the Pulse Limit Note Setting a pulse limit only makes sense when a heart...

Страница 31: ...device PC ECG Spirometer etc Pre requisite for this is that the attached device is compatible with the interface protocol of the ergometrics er800S A 1 Input and Output Pin Specifications J 2 J 3 Ana...

Страница 32: ...terface for an er800S Data Connection to PC or ECG Voltages logic low logic high Transmit Output Pin 1 7V 7V Receive Input Pin 5 3V 3V Baud rate 4800 Baud Protocol Format ASCII Start bits 1 Data bits...

Страница 33: ...ergometry P xxx CR Pulse limit is set to xxx 1 min only required for pulse steady state training S CR or Start ergometry with initial load Po s CR B CR B xxx CR Request for current load value return...

Страница 34: ...Operation Manual Ergometer Type er800S er800S Operation Manual 26 Version 05 02 Art Nr 475 051 Appendix A Interfaces...

Страница 35: ...te programs If the ECG unit used has a QRS trigger output it can be connected to the ergometer There are two possible points of connection see Appendix A Either via the opto input J3 Pin 5 or via the...

Страница 36: ...Operation Manual Ergometer Type er800S er800S Operation Manual 28 Version 05 02 Art Nr 475 051 Appendix B HR Input...

Страница 37: ...ge source with a value of between 1V and 3V to service connector A The displayed load value may now be adjusted to the calibrated voltage source 1 00V 100 watt by using the yellow arrow keys Service c...

Страница 38: ...between 3 and 6kg on the calibration hooks see picture below In the leftmost display a value will now appear Use the yellow arrow keys to adjust this value for the weight hung e g 3 50 for a weight of...

Страница 39: ...5 W 2 min or 50W 3 min Training Puls Steady State Program Maximum patient weight 120 kg Seat adjustment adjustable for body heights of 1 20m to 2 10m Handle bar adjustment height and angle adjustable...

Страница 40: ...Type er800S er800S Operation Manual 32 Version 05 02 Art Nr 475 051 Appendix D Specifications The Speed correlated Capacity of Brake Power Control RPM independent range in accordance with DIN 13405 RP...

Отзывы: