background image

21 

 

7

 

ENVIRONMENT AND QUALITY 

The Luna has an expected lifetime of a minimum of 10 years under the assumption that all 

recommended service checks have been carried out and that the normal maintenance and 

care instructions have been followed.

 

 

Disposal 

Disposal of the equipment can be made through Winncare Nordic. After Luna’s useful lifetime 

Winncare Nordic will receive the unit back and split the individual fractions in an 

environmentally friendly way either through reuse or recycling. 

Fractions that contain aluminium, lead acid batteries, ABS plastic, steel may damage the 

environment if not handled in an environmentally responsible way.

 

 

Battery 

The Luna is equipped with batteries which may be returned either to the local recycling station 

or to Winncare Nordic at the end of their lifetime.

 

 

Quality 

Winncare Nordic is certified according to the quality standard ISO 9001 and ISO 13485. 
These certifications mean that the products and the company comply with the international 

standards for quality management and standards for traceability of medical products. 

Luna

IPx4

/200 and Luna

IPx4

/275 is classified as a Medical device class 1 product.

 

 

Symbols and abbreviations 

 

Direct current 

 

Double insulated 

 

Type B, patient is not separated from the ground 

 

The product should be recycled where possible 

 

Refer to the user manual 

 

Safe working load = (user + sling) 

SWL 

Содержание LunaIPx4

Страница 1: ...this user manual carefully before using the product This user manual is intended as a guide for caregivers and other users as well as technical personnel during servicing and maintenance of the produ...

Страница 2: ...2...

Страница 3: ...lifting slings ___________________________________________________14 Room to room transfer _______________________________________________15 Using Luna in a shower or bathing environment_____________...

Страница 4: ...ts must be mounted correctly and according to this user manual There must be no indication of wear and tear on the Luna track system or lifting sling NEVER begin lifting if there is suspicion of any d...

Страница 5: ...n environment containing chlorine or in other aggressive environments Safety checks Check lifting strap for wear and tear or damage If there is any sign of a defects the Luna must be taken out of use...

Страница 6: ...ment to Winncare Nordic in case of repair or annual check Contents of the box Luna cassette User manual Hand control accessories Spreader bar accessories Charger accessories Transport The Luna is most...

Страница 7: ...s indicates correct mounting If the Luna is not mounted correctly an electronic safety device prevents to operate Detaching the Luna from the cart 1 Push the Luna upwards toward the cart feel easy res...

Страница 8: ...with extension arm can be purchased from Winncare Nordic or dealer See order number in section 8 Accessories Mounting and detaching of the spreader bar Depending on how the Luna is mounted the spreade...

Страница 9: ...na when connecting you will feel a light resistance from spring 2 Now turn the Luna clockwise 90 and await a little click this indicates correct mounting see fig 2 2B If the spreader bar is not mounte...

Страница 10: ...ary to lower a patient safely in case of a lift failure This button must be held constantly to lower the unit See section 2 5 8 STOP Press the emergency stop button to stop the Luna immediately This f...

Страница 11: ...control The Emergency stop can be deactivated by pressing the Reset button on the handset for 5 seconds Emergency lowering button Emergency lowering is only to be used in an emergency where it is nec...

Страница 12: ...hand control Fig 2 Remove the plug on the side of the Luna Fig 3 Take the key which is placed at the top of the charger Put the key into the Luna and turn the key counter clockwise to lower the user N...

Страница 13: ...When charging starts the LED on the hand control and front panel will flash o After 2 minutes the flashing stops but the Luna continues charging To check the charging status simply remove and reinsert...

Страница 14: ...accidents null and void Winncare Nordic can assist in choosing slings and the correct use of slings Attaching slings to the Winncare Nordic spreader bar Winncare Nordic accepts no responsibility if s...

Страница 15: ...her as possible 2 The lifting strap from Luna b is extended and attached to the extra suspension point on the spreader bar 3 Now both Lunas are connected to the spreader bar Check that the hook from t...

Страница 16: ...ore the Luna is mounted on the cart 1 In this lifting situation Luna a is moved as close as it is possible to the carts 2 Luna a with user is moved to the door and the transfer strap b from the other...

Страница 17: ...proof IPx7 hand control which withstands to be immersed in water 4 MAINTENANCE Cleaning The Luna may be cleaned using a slightly damp cloth with a small quantity of standard household cleaning agents...

Страница 18: ...Winncare com Troubleshooting Fault Possible cause Solution Luna does not react when the hand control UP DOWN are used no beep sound from the Luna unit Luna is not on or emergency stop is activated Tu...

Страница 19: ...get a new one from the dealer or Winncare Nordic 6 TECHNICAL DATA AND DIMENSIONS Technical specifications Max capacity Length of lifting strap Weight Measurements Battery operation Charging Covering...

Страница 20: ...0 mm 6 7 In D Min height from hook to track 430 mm 16 9 In E Lifting range from min height 1950 mm 76 7 In Measurements strap mounted A Width of Luna cassette 320 mm 12 6 In B Spreader bar see section...

Страница 21: ...vironment if not handled in an environmentally responsible way Battery The Luna is equipped with batteries which may be returned either to the local recycling station or to Winncare Nordic at the end...

Страница 22: ...cable 2 channels Standard spreader bar Luna 015 02108 015 02110 015 01968 015 02122 015 02124 015 01974 Spreader bar Strap 36 cm 14 In Spreader bar Strap 48 cm 19 In Spreader bar Strap 58 cm 23 In Sp...

Страница 23: ...contact Up to 15kV air Suitable for use on wood concrete or ceramic floor materials Keep relative humidity below 30 when used on floors of syntenic materials e g carpets EN IEC61000 4 4 Electrical fas...

Страница 24: ...ation for the transmission frequency Recommended safe distance d 1 17 P for 80 MHz to 800 MHz d 2 33 P for 800 MHz to 2 5 GHz with P as the maximum rated power of the transmitter in watts and d the re...