background image

2

3000044983

English

 Read the instructions carefully  

 

    before installation and commis- 

     sioning! 

 Leave the instructions for users/ 

 

    customers for future reference!

 Our updated product documen- 

 

    tation can be accessed at  

     www.erco.com/download.

General safety information

 

 Warning! 

   

Risk of electric shock! 

Before carrying out maintenance and 

installation on the luminaire, disconnect 

from the mains supply and also from 

any other DALI control wiring, and 

ensure that all power is switched off.

Attention!

- Do not open the luminaire head. In 

case of damage or a defective LED 

module, the entire luminaire must be 

returned to the factory.

- Do not operate luminaires with 

damaged or missing safety glass.

- When installing, always observe the 

national installation and accident pre-

vention regulations.

Intended use

The luminaire is suitable for outdoor 

and indoor use and is approved for a 

height of light source exceeding 15m. 

Dimensions (D), max. reference plane 

for wind loads (A) and weight (W) are 

detailed in Fig. 5.

Choosing the mounting location

Position the luminaire so as to avoid 

operation in direct sunlight or near 

other sources of heat. High ambient 

temperatures can reduce the life and 

efficiency of the control gear or LED 

module.

Electrical installation

For 3-circuit installation: to avoid any 

damage to the control gear, the neutral 

conductor must never be connected or 

disconnected during operation.

Overvoltage protection

ERCO uses electronic control gear with 

overvoltage protection in accordance 

with DIN EN 61547. If additional protec-

tion from spikes is required, e.g. when 

switching off inductive loads, separate 

overvoltage protection units should be 

installed.

Luminaire with DALI control gear

- All cables, materials and devices used 

must be suitable for mains voltage, as 

the DALI signal is not transmitted using 

safety extra low voltage (SELV).

- For general information on DALI, 

please go to: www.dali-ag.org.

Notes on corrosion protection 

Ensure that the powder coating is not 

damaged during installation or mainte-

nance work. Any damage, which becomes 

wet, can result in corrosion occurring. In 

aggressive environments, the installation 

and maintenance of all parts will require 

the appropriate protective measures. Che-

micals damage the corrosion protection.

Mounting

1. Detach the mounting plate from the 

luminaire. Remove the connector bet-

ween luminaire and mounting plate.

2. Drill fixing holes (Fig. 1/2).

3. Insert the connection cable into the 

mounting plate. Refer to Fig. 3. 

4. Attach the mounting plate diagonally 

using 2 heavy load rawl bolts M8 accor-

ding to the manufacturer’s instructions. 

Attention! Always select fittings in com-

pliance with the national regulations and 

standards applicable to the installation 

site. Ensure suitable corrosion resistance 

as required for the environment.

5. Make the electric connection. Con-

nect the earth conductor to the moun-

ting plate. 

6. Reattach the connector.

7. Fit the luminaire to the mounting 

plate and push towards the fixing screw 

(Fig. 4). Tighten the fixing screw.

Flashing of the LED module 

It is normal for the LED module to flicker 

when switching on and off.

Dimming

Depending on the model, the luminaire 

can be dimmed using a suitable dimmer 

(trailing edge) or via DALI.

Trailing-edge dimmers

Follow the manufacturer’s installation 

instructions. For some products, the 

luminaire can only be switched on in the 

upper dimming range. Before installation 

and connection, check luminaire, control 

gear and dimmer combination for proper 

functioning of the dimmer, especially 

when using universal dimmers. 

The use of dimmers which are unsuit able 

for LED drivers can damage the lumi-

naire, control gear and/or the dimmer.

No responsibility is accepted for the 

use of dimmers that are unsuitable for 

the luminaire.

Cleaning

Always clean carefully using a soft 

cloth and a commercially available, 

ph-neutral, alcohol-free, non-abrasive 

cleaning agent.

Take care not to damage the powder-

coating.

Cleaning the safety glass

Safety glass can be cleaned with clea-

ning agents that are also suitable for 

glass-ceramic cooking hobs.

Disposal 

 In accordance with EU Directive  

 

WEEE (Waste Electrical and Electro-

nic Equipment), luminaires must not 

be disposed of with other household 

waste. At the end of their life, lumi-

naires must be taken to the appropriate 

local facility available for the disposal 

or recycling of electronic products.

Отзывы: