8.2.3.2 Output –
GenPro 23e
Table: Characteristics of the open-collector output
Characteristics
Symbols
Conditions
Max.
Unit
max. tension
V
CE0
Open
transmitter
80
V
DC
max. tension
V
CES
V
BE
= 0 V
60
V
DC
Collector current
I
C
1
A
Saturation tension
V
CEsat
I
C
= 500 mA
1.3
V
Dissipation P
Ttot
T
amb
≤
25 °C, T
j
= 110 °C
0.78
W
Electric scheme of the output
No protection is provided. The user must respect the values of the table above.
8.2.3.3 Analog input –
GenPro 23e
As an option on the
GenPro 23e
, it is possible to have an analog input instead of the opto-coupled input E2.
This analog input allows to do a measure in tension (contact us).
Table: Characteristics of the analog input option
Characteristics
Min. value
Max. value
Command tension
0 V DC
10 V DC