Chapter 5: CCM Appliance Commands
43
Port Alert Add command
The Port Alert Add command adds a port alert string to a specified port. Each port may have up to
ten port alert strings. Duplicate strings are not allowed on the same port. To generate a trap, the
Server SNMP Trap command must be issued to enable the PortAlert trap. For more information,
see
Managing the CCM Appliance Using SNMP
Access right: SCON or PCON
Access level: ADMIN or APPLIANCEADMIN
Syntax
PORT <
port
> ALERT ADD “<
string
>”
Port Alert Copy command
The Port Alert Copy command copies the alert strings from one port (from_port) to another
(to_port). Any alert strings that were previously defined on the to_port will be deleted. When you
enter this command, you are prompted to confirm or cancel the copy operation.
For more information, see
Managing the CCM Appliance Using SNMP
Access right: SCON or PCON
Access level: ADMIN or APPLIANCEADMIN
Syntax
PORT <
to_port
> ALERT COPY <
from_port
>
Example
The following command copies the alert strings defined on port 1 to port 17, replacing any
previously defined alert strings on port 17.
port 17 alert copy 1
Table 5.4: Port Alert Add Command Parameters
Parameter
Description
<
port
>
Port number in the range 1-48.
<
string
>
3-32 character string. If the string contains embedded spaces, it must be enclosed in
quotation marks.
Table 5.5: Port Alert Copy Command Parameters
Parameter
Description
<
to_port
>
Port number where alert strings will be copied, in the range 1-48.
<
from_port
>
Port number from which alert strings will be copied, in the range 1-48.
Содержание Equinox Console Manager CCM4850 CCM4850 CCM4850
Страница 8: ...vi CCM4850 Installer User Guide...
Страница 10: ...viii CCM4850 Installer User Guide...
Страница 16: ...4 CCM4850 Installer User Guide...
Страница 44: ...32 CCM4850 Installer User Guide...
Страница 82: ...70 CCM4850 Installer User Guide...
Страница 94: ...82 CCM4850 Installer User Guide...