background image

Notice:  

• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield 

conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer 

casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special Note: Line termination:

      • When longer runs of cable are used, you may need to use a terminator on the last unit to 

        avoid erratic behaviour.

Using a cable terminator (part number CABL90) will decrease the possibilities of erratic 

behaviour. 

5-Pin XLR DMX Connectors:

     • Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin 

       XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin 

       XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the 

       correct cable conversion.

Termination reduces signal transmission problems 
and interferance. it is always advisable to connect a 
DMX terminal, (resistance 120 Ohm 1/4 W) between 
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

 Equinox Trinity Beam Laser 

 

 

 

 

                                      DMX Set Up

Содержание EQLA42

Страница 1: ...Order code EQLA42 User manual...

Страница 2: ...SING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and d...

Страница 3: ...r cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has be...

Страница 4: ...50 x 392 x 110mm Weight 4 6Kgs Fuse 2A Features The Trinity Beam Laser features 7 DMX channels and many laser patterns that are ideal with or without fog Equinox Trinity Beam Laser Technical specifica...

Страница 5: ...patterns 3 DMX mode To select DMX mode set dip switch 10 to OFF You can now set the required DMX address using dip switches 1 to 9 Please refer to the chart below for DMX functions The DMX address sta...

Страница 6: ...the chain starts at 107 Set the start address using the group of dip switches located usually on the back of the fixture Each dip switch has an associated value Adding the value of each switch in the...

Страница 7: ...in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the e...

Страница 8: ...terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XL...

Страница 9: ...Equinox Trinity Beam Laser Dip Switch Reference Chart DMX Dip Switch Quick Reference Chart Dip Switch Position Dip Switch position DMX Address...

Страница 10: ...used for lighting displays can be harmful if not properly setup or is misused But when used following the recommended health and safety guidelines laser lighting effects no more harmful than looking...

Страница 11: ...ass 1 laser products Laser Pointers output more accessible power than CD DVD players and are normally limited to being Class 2 devices While most laser lighting effects products are Class 3B and Class...

Страница 12: ...order to own or operate a laser for lightshow use However there is specific guidance issued by the Health and Safety Executive in the form of a document called HS G 95 The Radiation Safety of Lasers U...

Страница 13: ...he Keyswitch is provided to help limit the use of the laser projector to those that have key access Without the key inserted and in the on position the laser will not emit an output The idea behind la...

Страница 14: ...Safety Officer LSO The Laser Safety Officer should be aware of the safety issues when using lasers and is responsible for overseeing how the laser is used In smaller businesses the LSO will probably a...

Страница 15: ...ght specified is not the height of the actual projector but it refers to the height of the laser effect Therefore having the laser projector positioned at 3m height and aimed directly down is not what...

Страница 16: ...ble below to give an idea of the distances involved Laser Output Power 10mW 30mW 50mW 100mW 250mW 450mW Hazard Distance 12m 20m 25m 36m 56m 76m Table 1 Static Beam Hazard Distances Note The values hav...

Страница 17: ...2008 Guidance for Laser Displays and Shows Issued by British Standards Institute Website www bsigroup co uk PD IEC TR 60825 14 2004 Laser Safety User Guide User Guide Issued by British Standards Insti...

Страница 18: ...Notes Equinox Trinity Beam Laser Notes...

Страница 19: ......

Страница 20: ...www prolight co uk...

Отзывы: