background image

  

       

INDICATION. 

 [

]: Rectangle duct XY dimension 

indication. 

  h : Hour indication. 

  m : Minute indication. 

  S : Second indication. 

  in : Inches indication. 

  cm : Centimeter indication. 

  ft

2

   : Square feet indication. 

 m

2

  : Square meters indication. 

 
 

6. POWER ON/OFF 

Press 

  button to turn on or turn off the power. 

 

7. Auto power off   

The duration of auto power off time is 15 minutes. 

If you want disable auto power off, please hold 

  button and press 

  button at the power 

shutdown mode. When you see the “n-SL” display 

on the LCD, that means the auto power off 

function is off. If you want enable auto power off, 

please restart the meter. 

 

       

  

 

8. BACKLIGHT   

Press 

  button to turn on the backlight, pres 

this button again to turn it off. 

The backlight time is 15 seconds. 

9. CHANGE AIR VELOCITY UNIT 

Press 

  button to change the air velocity 

unit.  

m/s

knots

km/hr

mile/hr

ft/min

Beaufort 

10.  CHANGE UNIT   

Press 

  button and 

  button to change 

unit. 

<=>

, m

<=>

ft 

11.  CHANGE FUN CTION 

Press 

  button and 

button to change 

function.  

 

 

         12.  TIME CONSTANT SETTING MODE

          

Press

button to select TC and press

           

button to into the time constant setting mode and press 

 

           to exit the time constant setting mode. 

Содержание EQ-TM- 4001

Страница 1: ...correct specification of the battery and correctly installed in the battery holder 25 END OF LIFE Caution This symbol indicates that equipment and its accessories shall be subject to a separate colle...

Страница 2: ...obe Instant AVG 2 3V MAX flow measurement Max A VG Min data hold function Low batter indication LCD triple display with LED backlight Manual data memory and read function 99 recor ds TM 4001 Auto pow...

Страница 3: ...rned when you have finished testing the high wind speed more than 20m s and remove the probe To extend the probe hold the handle in one hand while pulling on the probe tip with the other hand Do not h...

Страница 4: ...bration time is 10 minutes After end of the 33 0 RH calibration you can press button to shut do wn or press button to into 75 RH calibration D Humidity calibration 75 RH Put the probe in the 75 RH cha...

Страница 5: ...s button to select the 10 00m s and press button to st art calibration 10m s The duration of calibration time is 5 minutes After end of the 10m s calibration then will be into the normal display C Hum...

Страница 6: ...more than 2 seconds to disable this feature 18 CALIBRATION Please shut down the meter first then hold and press button and pr ess button to enter into calibration mode It will show 0 00 m s on the up...

Страница 7: ...le or disable hold function The HOLD function will be unavailable if calibration function is enabled RH humd i ity indication C Degree Celsius C Degree Fahrenheit hPa Hectopascal indication inHg Inch...

Страница 8: ...ee the n SL display on the LCD that means the auto power off function is off If you want enable auto power off please restart the meter 8 BACKLIGHT Press buttonto turn on the backlight pres this butto...

Отзывы: