Equinox Systems Confetti Burst EQLED400 Скачать руководство пользователя страница 4

www.prolight.co.uk

Confetti Burst

 

User Manual

4

Operating instructions

Button 1 – Channel 1

Button 2 – Channel 2

Button 3 – Channel 3

Button 4 – Channel 4

Wireless remote control operation:

To control the fixture via wireless remote control first set the channel on the control panel of the unit. 
E.g. If channel 1 is set then to activate  the unit press the 1 button on the RF remote. This function  
allows multiple fixtures to be triggered at different times, controlled from one remote.
Ensure the handheld remote is fitted with a good quality battery (A23 12V Alkaline).  
Press the correct button as per the list below to select the required mode of operation.

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX address, press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons  

to set the required DMX address. Press the 

“ENTER”

 button to confirm the setting.

 

Manual operation mode:

To access manual operation, press both the 

“MENU”

 and 

“ENTER”

 buttons together to activate.  

Press both buttons again to deactivate.

Wireless remote control

Control panel

Содержание Confetti Burst EQLED400

Страница 1: ...Order code EQLED400 Confetti Burst User Manual...

Страница 2: ...t connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sour...

Страница 3: ...tion Bracket allows for multiple rigging or floor standing applications 4 push button menu with LED display PowerCON input 3 Pin XLR input output Wireless remote included Confetti Burst Specifications...

Страница 4: ...ood quality battery A23 12V Alkaline Press the correct button as per the list below to select the required mode of operation DMX mode Operating in a DMX control mode environment gives the user the gre...

Страница 5: ...n rigging derigging or servicing do not allow personnel to be directly underneath the unit The operator must always make sure that the safety relating and machine technical installations are approved...

Страница 6: ...ll makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmis...

Страница 7: ...le adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 S...

Страница 8: ...sible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material r...

Отзывы: