DMX mode

To access the DMX mode, press the 

“MODE”

 button to show “

Addr”

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 or 

“DOWN”

 buttons to set the desired DXM address from 000-512.

For the DMX functions, please see the DMX chart below.

 Operation

Channel

1

2

3

4

Value

000-125

000-125

000-125

000

126-255

126-255

126-255

001-255

Function

No function

No function

No function

No function

Red + Amber @100%

Green @ 100%

Blue @ 100%

Colour chase

Daisy Chain Connection

1) Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin

    connector of the first fixture

2) Connect the end of the cable coming from the first fixture which will have a (female) 3 pin

    connector to the input connector of the next fixture consisting of a (male) 3 pin connector.

    Proceed to connect from the output as stated above to the input of the following fixture

    and so on.  

Содержание 2M Flight CasedDMX LED Flame Machine

Страница 1: ...User Manual Equinox 2M Flight Cased DMX LED Flame Machine Order code FLAM12 w w w p r o l i g h t c o u k...

Страница 2: ...Safety...

Страница 3: ...dically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to...

Страница 4: ...4 push button menu with LED display IEC power in socket 3 pin XLR in out sockets High velocity fan not suitable for low noise applications Supplied in full flight case Heavy duty industrial grade han...

Страница 5: ...C9 and Cb to zero the LED flame machine will have no LEDs on blackout If you set Cr to 99 and C9 and Cb to zero the LED flame machine will be 100 Red and Amber To add strobe press the ENTER button and...

Страница 6: ...1 255 Function No function No function No function No function Red Amber 100 Green 100 Blue 100 Colour chase Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the outp...

Страница 7: ...a is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking DMX is a...

Страница 8: ...Using a cable terminator part number CABL90 3 pin or CABL89 5 pin will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data tra...

Отзывы: