![Equalizer AIR CART Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/equalizer/air-cart/air-cart_operators-manual_2420536040.webp)
AIR DELIVERY SYSTEM
39
EQUAL DISTRIBUTION CHECK ON FAN MANIFOLD
Fan diffusers are equipped with 2 setting tabs which ensures the equal distribution of air
between the various outlets. This setup is done in the factory. If the distribution is uneven, the
following procedure will rectify it:
1. Adjustments are made with the fan running and the pipes disconnected from the diffuser.
2. The test for equal distribution is simply felt by hand. Adjust and lock the two tabs in position
once equal distribution is achieved.
NOTE:
Exact equal distribution of air for all practical purposes is impossible, but close enough
is sufficient. Connecting the hoses back onto the manifold has a positive effect on flow
distribution as the increased back pressure aids in equal division.
IMPORTANT:
If a differential pressure between seed and fertilizer lines is required for Air Carts
equipped with a single fan, adjust the division to achieve the desired pressure difference.
Setting tabs
Содержание AIR CART
Страница 1: ...0 OPERATOR MANUAL AIR CART...
Страница 5: ...IDENTIFICATION 4 IDENTIFICATION Record the Air Cart s data on the name tag below...
Страница 21: ...FRAME 20...
Страница 28: ...AUGER 27 Bottom position Side position Spring bolt...
Страница 47: ...MAINTENANCE AND INSPECTION 46 9 3 LOCATION OF GREASE POINTS Front steering axle...
Страница 48: ...MAINTENANCE AND INSPECTION 47 Auger A Auger bearing B Inner swing arm hinge A B C D E...
Страница 49: ...MAINTENANCE AND INSPECTION 48 C Outer swing arm hinge D Auger rotation hinge E Auger tilt hinge...
Страница 53: ...TROUBLESHOOTING 52 SCHEMATICS...
Страница 54: ...TROUBLESHOOTING 53...