90
91
20. Information about radio operation
Radio transmission is performed on a non-exclusive
transmission path, which means that there is a possibility
of interference occurring. Interference can also be caused
by switching operations, electrical motors or defective
electrical devices.
The range of transmission within buildings can differ
greatly from that available in the open air. Besides the
transmitting power and the reception characteristics of the
receiver, environmental factors such as humidity in the vi-
cinity have an important role to play, as do on-site struc-
tural/screening conditions.
eQ-3 Entwicklung GmbH hereby declares that this device
complies with the essential requirements and other
relevant regulations of Directive 1999/5/EC. You can find
the full declaration of conformity at www.eQ-3.de.
21. Technical characteristics
Short description:
BC-RT-TRX-CyG-2
Supply voltage:
3 V
Max. current consumption:
100 mA
Batteries:
2x LR6 batteries
(mignon/AA)
Battery life:
2 years approx.
Display:
LCD
Receiver frequency:
868.3 MHz
Typical open air range:
100 m
Receiver class:
SRD Class 2
Method of operation:
Type 1
Degree of protection:
IP20
Housing dimensions:
60 x 65 x 100 mm
(W x H x D)
Weight:
170 g (without batteries)
Connection:
M30 x 1.5
Ambient temperature:
+5 to +55°C
Linear travel:
4.2 mm
Spring force:
Max. 80 N
Maximum number of devices to teach-in:
MAX! House Solution:
•
max. 50 devices in max. 10 rooms,
•
max. 4 MAX! Eco Switches
•
max. 8 MAX! Radiator Ther), 8 Window Sensor
and 1 MAX! Wall The per room.
MAX! Room Solution:
•
max. 1 MAX! Wall The
•
max. 8 MAX! Radiator Ther)
•
max. 8 MAX! Window Sensors
MAX! Radiator Solution:
•
max. 2 MAX! Radiator The
•
max. 3 MAX! Window Sensor
Subject to technical changes.