1-2
System Preparation
Rev. B
Confidential
The maximum transmission speed is 115.2k bps when using a serial interface.
(*) Handshaking, communications speed, data bit length and parity are set by DIP switches on the TM Printer.
Interface Cable
Prepare a serial or USB interface cable according to customer requirements. Note that while the
standard serial interface of the TM printers uses a 25-pin D-sub connector, the UB-U09 uses a
9-pin D-sub connector.
Table 1-1 shows the recommended wiring for the interface cable.
Supported standard
EIA/TIA RS-232 standard compliant
Data transfer method
Bit Serial
Synchronization
(Asynchronous)
Handshaking*
DTR/DSR or XON/XOFF control
Signal level
Mark: -3 to -15 V = Logic 1, OFF
Space: +3 to 15 V = Logic 0, ON
Communications speed*
(Baud rate)
115200 bps maximum
Data bit length*
7 or 8 bits
Parity*
None, Odd or Even
Stop bits
One or more bits
Table 1-1 Recommended wiring
Host side
UB-U09 side (Female 9-pin D-sub)
---
Pin 1 not connected
TXD
Pin 2 RXD
RXD
Pin 3 TXD
DSR
Pin 4 DTR
SG
Pin 5 SG
DTR
Pin 6 DSR (*1)(*2)
CTS
Pin 7 RTS
Reset
Pin 9 INIT(*2)
Frame GND
Frame GND