DISASSEMBLY/ASSEMBLY
Disassembling Printer Mechanism
46
Confidential
4.5.3 CR Scale
Part/Unit that should be removed before removing CR Scale
Upper Housing
Removal Procedure
1.
Release the right end of the CR Scale from the tab.
2.
Release the CR Scale from the slit of the CR Encoder Sensor.
Figure 4-23. Removing CR Scale (1)
3.
Release the Extension Spring 3.289 from the hook of the Main Frame.
4.
Rotate the CR Scale 90 degrees as shown in the figure and remove the scale
from the Main Frame.
Figure 4-24. Removing CR Scale (3)
C A U T I O N
Pay attention to the following instructions:
•
Do not touch the CR Scale with bare hands.
•
Do not damage the CR Scale.
•
Do not stretch Extension Spring 3.289 too much.
CR Scale
Tab
CR Scale
Epson Stylus C79/D78’s Case
Slit of CR Encoder Sensor
Tab
CR Scale
Epson Stylus C58/C59/ME2’s Case
When installing the CR Scale, pay attention to the following
instructions.
The CR Scale must be set between the sides of the CR Encoder
Sensor, but not touching either side. If the CR Scale is rubbing
against either wall (emitter or receiver), it should be re-
installed.
Chipped part of the CR Scale should be facing upward.
Extension Spring 3.289 should not be twisted.
CR Scale
Extension Spring 3.289
Hook
Chipped
90
º
Содержание Stylus S20
Страница 9: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 27: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 31: ...Confidential C H A P T E R 1 4 DISASSEMBLY ASSEMBLY ...
Страница 69: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 78: ...Confidential C H A P T E R Y 6 MAINTENANCE ...
Страница 84: ...Confidential C H A P T E R 7 APPENDIX ...