SC-F9200 Series
Revision B
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
170
SE Group Confidential (Related Staff Only)
3.4.5.15 Pump Cap Unit 1
1.
2.
Remove the Media Loading Lever.
3.
Remove the Panel Unit.
4.
Remove the Right Upper Cover.
5.
Remove the Right Front Cover.
6.
Remove the Right Cover.
7.
Move the CR Unit to a position over the platen.
8.
Disconnect the cables from the three relay connectors (No.36, No.37, and No.79).
Figure 3-111. Disconnecting from the Relay Connectors
A D J U S T M E N T
R E Q U I R E D
When replacing/removing this part, refer to
Items and the Order by Repaired Part” (p260)
and make sure to
perform the specified operations including required adjustment.
No.36
No.37
No.79
* “No.36 L”, “No.37 L”, and “No.79 L” are
indicated on the connectors at the main
body side.
C H E C K
P O I N T
Leave the relay connectors at the main body side to reuse them.
Relay Connector