background image

© Seiko Epson Corporation. 2022

Only five minutes!

How to use Epson DMM board

Rev1.00

The contents of this document are subject to change without notice.

Содержание S5U1C17M03T

Страница 1: ... Seiko Epson Corporation 2022 Only five minutes How to use Epson DMM board Rev1 00 The contents of this document are subject to change without notice ...

Страница 2: ...2 1 Introduction 2 DC voltage measurement 3 Characteristic value 1 Recording characteristic values 2 Checking characteristic values 4 Appendix 5 Manual Agenda ...

Страница 3: ...d S5U1C17M03T has a digital multimeter function loaded in the flash ROM various measurements can be performed simply by turning on the power 1 Introduction S5U1C17M03T Evaluation board of MCU S1C17M03 for digital multimeter ...

Страница 4: ...EAS T13 T12 Set 0 to the mark at the bottom center Short the part of the red frame Connect the PC and board with a USB cable TypeC to supply power Settings Measurement 1 500V Check the display Connect the probe Connect the probe to the measurement target 1 2 3 4 5 1 2 Short the part of the red frame ...

Страница 5: ...robe to the measurement target Start DmmEvalTool exe from the software package Connect the PC and board with a USB cable TypeC to supply power Push SW2 Check COM is displayed COM Example DC voltage measurement 1 2 3 4 5 Operate the tool on the next page ...

Страница 6: ...Click START to start reading the data Press SW2 at any time to finish reading the data When reading is completed a Logs folder will be created and the measurement data Output csv will be saved in that folder 1 2 3 Example DC voltage measurement ...

Страница 7: ...urement data gets 16 bit digital values Excludes Capacity measurement and Frequency measurement Please close the csv file when recording the characteristic value Data number of measurement Range of measurement Mode of measurement A column is added each time you record Open Output csv and check the characteristic value ...

Страница 8: ...8 4 Appendix ...

Страница 9: ...ance CC method 600Ω OHM CC short short short open open open open 5 Resistance CV method 600Ω OHM CV short short short open open open open 6 Continuity check CV CONT short short short open open open open 7 Capacitance CC method 1uF CAP CC short short short open open open open 8 Capacitance CV method 10nF CAP CV short short short open open open open 9 Diode VF DIODE short short short open open open ...

Страница 10: ...f the procedure 2 No offset correction has been performed Therefore the actual input value and the value displayed on the LCD panel will differ 3 It may be affected by power supply noise depending on the measurement environment Cautions for measurement Measurement mode affected by power supply noise AC voltage and frequency AC current and frequency Capacitance CC method Capacitance CV method ...

Страница 11: ...11 5 Reference manual Information Document MCU S1C17M02 03 S1C17M02 03 Technical manual Evaluation board S5U1C17M03T S5U1C17M03T Manual Software Application note ...

Страница 12: ...guarantee that the information and the programs are always accurate and complete Epson assumes no responsibility for any damages which you incur due to misinformation in this document and the programs 6 No dismantling analysis reverse engineering modification alteration adaptation reproduction etc of Epson products is allowed 7 Epson products have been designed developed and manufactured to be use...

Страница 13: ...13 ...

Отзывы: