Appendix D Mask Data Creation Procedure
This chapter shows a procedure to create an S1C630 Series (S1C63003/004/008/016) mask data file (PA
x
) for sub-
mission to Seiko Epson. Use the appropriate device information definition file according to the model to be used.
Note: Before creating the mask data file, get the latest device information definition file package listed
below from our website.
*
1
S1C63003 device information definition file version 5.0 or later
S1C63004 device information definition file version 6.0 or later
S1C63008 device information definition file version 4.0 or later
S1C63016 device information definition file version 1.0 or later
Mask Data Creation Flowchart
D.1
Create function option file
(FDC)
See Section D.2.
Create segment option file
(SDC)
See Section D.3.
Create mask data file
(PA
x
)
See Section D.4.
1.1 Mask data creation flowchart
Figure D.
Function Option File Creation Procedure
D.2
The following shows a procedure to create a function option file:
1. Launch the function option generator (winfog.exe).
2. Load the device information definition file (INI).
Select "Device INI select" from the "Tool (T)" menu or click the "Device INI select" button.
When the dialog box appears, select the folder and file (INI) for the target model.
• Folder: 630
xx
*
2
• File:
630
xx
.INI
*
2
3. Set up information such as the output folder/file name.
Select "Setup (S)" from the "Tool (T)" menu or click the "Setup" button.
Enter the information required through the dialog box appeared.
4. Select options to be used.
5. Generate the function option files (FDC, FSA).
Select "Generate (G)" from the "Tool (T)" menu or click the "Generate" button.
The function option files will be generated.
Segment Option File Creation Procedure
D.3
The following shows a procedure to create a segment option file:
1. Launch the segment option generator (winsog.exe).
2. Load the device information definition file (INI).
Select "Device INI select" from the "Tool (T)" menu or click the "Device INI select" button.
When the dialog box appears, select the folder and file (INI) for the target model.
• Folder: 630
xx
*
2
• File:
630
xx
.INI
*
2