APPENDIX A LIST OF PERIPHERAL CIRCUIT CONTROL REGISTERS
S1C17M20/M21/M22/M23/M24/M25
Seiko Epson Corporation
AP-A-23
TECHNICAL MANUAL (Rev. 1.0)
Address
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
0x500a T16B0INTF
(T16B Ch.0 Interrupt
Flag Register)
15–8 –
0x00
–
R
–
7–6 –
0x0
–
R
5
CAPOW1IF
0
H0
R/W Cleared by writing 1.
4
CMPCAP1IF
0
H0
R/W
3
CAPOW0IF
0
H0
R/W
2
CMPCAP0IF
0
H0
R/W
1
CNTMAXIF
0
H0
R/W
0
CNTZEROIF
0
H0
R/W
0x500c T16B0INTE
(T16B Ch.0 Interrupt
Enable Register)
15–8 –
0x00
–
R
–
7–6 –
0x0
–
R
5
CAPOW1IE
0
H0
R/W
4
CMPCAP1IE
0
H0
R/W
3
CAPOW0IE
0
H0
R/W
2
CMPCAP0IE
0
H0
R/W
1
CNTMAXIE
0
H0
R/W
0
CNTZEROIE
0
H0
R/W
0x5010 T16B0CCCTL0
(T16B Ch.0 Compare/
Capture 0 Control
Register)
15 SCS
0
H0
R/W –
14–12 CBUFMD[2:0]
0x0
H0
R/W
11–10 CAPIS[1:0]
0x0
H0
R/W
9–8 CAPTRG[1:0]
0x0
H0
R/W
7
–
0
–
R
6
TOUTMT
0
H0
R/W
5
TOUTO
0
H0
R/W
4–2 TOUTMD[2:0]
0x0
H0
R/W
1
TOUTINV
0
H0
R/W
0
CCMD
0
H0
R/W
0x5012 T16B0CCR0
(T16B Ch.0 Compare/
Capture 0 Data
Register)
15–0 CC[15:0]
0x0000
H0
R/W –
0x5018 T16B0CCCTL1
(T16B Ch.0 Compare/
Capture 1 Control
Register)
15 SCS
0
H0
R/W –
14–12 CBUFMD[2:0]
0x0
H0
R/W
11–10 CAPIS[1:0]
0x0
H0
R/W
9–8 CAPTRG[1:0]
0x0
H0
R/W
7
–
0
–
R
6
TOUTMT
0
H0
R/W
5
TOUTO
0
H0
R/W
4–2 TOUTMD[2:0]
0x0
H0
R/W
1
TOUTINV
0
H0
R/W
0
CCMD
0
H0
R/W
0x501a T16B0CCR1
(T16B Ch.0 Compare/
Capture 1 Data
Register)
15–0 CC[15:0]
0x0000
H0
R/W –
0x5040–0x505a
16-bit PWM Timer (T16B) Ch.1
Address
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
0x5040 T16B1CLK
(T16B Ch.1 Clock
Control Register)
15–9 –
0x00
–
R
–
8
DBRUN
0
H0
R/W
7–4 CLKDIV[3:0]
0x0
H0
R/W
3
–
0
–
R
2–0 CLKSRC[2:0]
0x0
H0
R/W