14. How to use
RX4111CE
Jump to
ETM62E-02
Seiko Epson Corporation
50
14.9. Flow Chart
The following flow-chart is one example, but it is not necessarily applicable for every use-case and not necessarily the
most effective process for individual applications.
1)
In Initial power on
VLF can not be cleared to "0" until internal oscillation starts.
Start
Wait
Wait time of 40 ms is necessary at least.
Whether it is a return from the state of the backup is confirmed.
VLF=1 ?
YES
YES
NO
VLF=
”0” clear
Wait
VLF=0 ?
NO
Please set waiting time depending on load of a system optionally.
It takes about 200 ms from Power ON to oscillation start.
Power on
Start-up complete
Initialize
Figure 39 Flow1