EPSON Stylus Photo R800
Revision A
TROUBLESHOOTING
Overview
57
At power-on
The power-on sequence is
executed but Fatal error is
displayed.
CR drive
system
1. Check that the Carriage Shaft is lubricated with grease.
1. Wipe the surface of the Carriage Shaft
with a dry, soft cloth, and lubricate the
Carriage Shaft with grease G-70. (Refer
to Chapter 6
At power-on, the PF Motor
does not operate at all.
PF Motor
1. Check that the PF Motor connector cable is connected to
the Relay Connector.
1. Connect the PF Motor connector cable to
the Relay Connector.
2. Using a tester, check the resistance value of the PF Motor.
Resistance value: 22.3
Ω
±
25%
2. If the resistance value is abnormal,
change the PF Motor for a new one.
3. Check the PF Motor connector cable for damage.
3. Change the PF Motor Cable for a new
one.
Table 3-14. Phenomenon-Based Fatal Error Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
Carriage Shaft
PF Motor
Relay Connector