EPSON Stylus Photo R800
Revision A
TROUBLESHOOTING
Overview
39
Table 3-2. Phenomenon-Based Communication Error Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
At power-on
The printer does not operate
at all.
Panel FFC
1. Check that the Panel FFC is securely connected to the
Panel Board connector and Main Board connector (CN8).
1. Connect the Panel FFC to the Panel
Board and Main Board connectors.
2. Check the Panel FFC for damage.
2. Change the Panel FFC for a new one.
Panel Board
1. Check the Panel Board for damage.
1. Change the Panel Board for a new one.
Power Supply
Board
1. Check that the Connector cable of the Power Supply
Board is securely connected to the Main Board (CN7).
1. Connect the Connector cable of the
Power Supply Board.
2. Check that the blue line side pin of the Power Supply
Board Connector cable is inserted into the 1 Pin. (Refer to
the above photo.)
2. Match and connect the blue line of the
Power Supply Board Connector cable
into the 1 Pin.
Panel Board
connector
Panel FFC
Panel FFC
Main Board
connector
Connector cable
of the Power
Supply Board
Blue line
1Pin side