Confidential
CR Motor
When routing the CR Motor cable through hooks C, D, E on the Main Frame, make sure to align the portions protected with acetate tape to hooks C, D, E.
Route the CR Motor cable as follows.
1. Route the CR Motor cable (black) around the rib A of the Frame Base (two turns). Do not apply too much tension on the CR Motor cable (black) then.
2. Route the CR Motor cable (red) through the rib B of the Frame Base, and then route it through the rib A taking care not to let the CR Motor cable (red)
come over the CR Motor cable (black).
3. Twist the CR Motor cable (black) and CR Motor cable (red) twice, and then route them through the hook C of the Main Frame.
4. Route the CR Motor cable (black) and CR Motor cable (red) in the order of hook D of the Main Frame, groove of the FFC Holder, dowel of the FFC
Holder, and hook E of the Main Frame.
CR Motor
Hook C
Hook E
Groove of FFC Holder
CR Motor cable
Hook D
Rib A
CR Motor cable (black)
CR Motor cable (red)
Rib B
Dowel of FFC Holder:
Route above dowel.
CR Motor cable
Do not apply too
much tension.