Expression 10000XL
Revision A
TROUBLE SHOOTING
Overview
26
3.1 Overview
This chapter explains the remedies for errors detected by the self-diagnostic function as
well as the check points on a fault phenomenon basis, which are required for efficient
troubleshooting at occurrence of any error.
3.1.1 Self-Diagnostic Function
This scanner has a self-diagnostic function that automatically diagnoses the operating
status of each section, and uses an LED indication to show the error state.This function
detects the following error states, and their remedies are as described below.
FATAL ERRORS
The status is defined as an error as soon as the paper feed/ejection command is
received.
COMMAND ERROR
COMMUNICATION ERRORS
Since the scanner doesn’t have SCSI, it doesn't correspond to communication errors.
OPTION ERRORS
Table 3-1. Fatal Errors
LED Indication
Cause
Corrective Action
READY
(Flashing)
ERROR
(Flashing)
• A Carriage home seek error at main
unit or TPU occurred.
1. Leaving the Carriage fixing lever
locked.
2. Motor connection error.
3. HP sensor fault/bad fit connection.
• A lamp check error of main unit or
TPU was detected.
1. Lamp fault, carriage adjustment error,
CCD output error.
2. FFC connection error of Lamp or
CCD.
• An error was detected in CCD output
level check.
• An unsupported board was inserted
into the option slot.
• Stop the Carriage and
put it in a hold state
(power off).
• Turn the Lamp off.
• Output shift pulses.
• Set the error bits (Bit 7)
of the status and
extended status.
• If the error was caused
by the option, set the
corresponding error bit
of the extended status.
• Display the fatal errors
on the LED.
Recovery
• Switch power off, then on again.
• Send the initialization command (ESC @).
• Make a bus reset using USB and IEEE1394.
Table 3-2. Command Error
LED Indication
Cause
Corrective Action
READY
ERROR
Received an undefined command or
undefined command parameter.
Sent an unsupported command.
Sent an unsupported setting parameter.
• Return NACK to the
incoming command/
parameter from the host.
• Display the command
errors on the LED.
Recovery
Recovers from command errors at the time of receiving a defined command.
Table 3-3. Option Errors
LED Indication
Cause
Corrective Action
READY
ERROR
• A Cover Open error occurred in TPU
option.
1. Opened the cover during the scanner
is in standby mode.
2. Sensor fault/bad fit connection.
• Set the corresponding
error bit of the extended
status.
• Do not set the error bit
(Bit 7) of the status and
extended status.
• Display the option errors
on the LED.
Recovery
Recovers from the errors after the causes are removed.
Содержание Expression 10000XL Series
Страница 1: ...EPSON Expression10000XL Color Flatbed Scanner SERVICE MANUAL IMAGE SESC04 001 ...
Страница 5: ...Revision Status Revision Date of Issue Description A May 14 2004 First Release ...
Страница 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 20: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 25: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 32: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Страница 64: ...C H A P T E R 5 ADJUSTMENT ...
Страница 67: ...C H A P T E R 6 MAINTENANCE ...
Страница 70: ...C H A P T E R 7 APPENDIX ...
Страница 74: ...Main Board 1 ...
Страница 75: ...Main Board 2 ...
Страница 76: ...Main Board 3 ...
Страница 77: ...SUB Board ...
Страница 78: ...Power Supply Board ...
Страница 79: ...Inverter Board ...
Страница 80: ...CCD Sensor Board ...
Страница 81: ...Panel Board ...
Страница 82: ...TPU Main Board ...
Страница 85: ...16 71 15 62 62 26 57 28 25 84 70 70 Rev 01 B168 ELEC 0011 ES 10000G Expression 10000XL No 2 72 ...
Страница 86: ...27 14 79 83 10 78 67 67 Rev 01 B168 MECH 0011 ES 10000G Expression 10000XL No 3 ...
Страница 87: ...26 58 82 81 52 90 61 18 64 64 48 49 Rev 01 B168 MECH 0021 ES 10000G Expression 10000XL No 4 51 ...