2-12
EMP-S4
SEIKO EPSON
Revision:B
2.5.2 Overview of Operation
The output cable of the power supply unit is connected to CN2000 on the MA board. It allows
the following voltages and signals to be transmitted.
•
DC output
•
The power supply On/Off signal (PWON)
The power supply fan reduces the internal heat in the power supply unit. The heated air
discharged from the power supply unit is then exhausted with the exhaust fan connected to
CN706 on the MA board.
C A U T I O N
Background power is still supplied to the MA board through CN2000
connector as long as the power cord is connected to the projector, even if the
[Power]
switch is turned off.
The EMI filter/regulator circuit eliminates interference (noise) from the AC
line and generates the DC voltage for the regulators.
The DC voltages shown in the tables below are generated by a Switching
Regulator. No fluctuations in output potential occur as a result of load
fluctuations, and the individual output voltages cannot be adjusted.
Table 2-2.
Output voltage
Output
voltage
accuracy
Ripple
(mVpp)
Ripple/
Spike
(mVpp)
Output current
Protection circuit Load capac-
ity (Refer-
ence) (
µ
F)
Signal
name
Voltage
Standby
mode
Min
Typ
Over-
voltage
Over-
current
+5
+5 V
±
5 %
100
200
20 mA to
220 mA
20 mA 3.5 A
-
Shutoff
100
+7
+7.2 V
+0.8 V/-
-0.4 V
100
200
0 A
0 A
0.5 A
-
Shutoff
200
+13
+13.8
+15 V ~
+13.5 V
200
300
0 A
0.2 A
1.5 A
-
Shutoff
100+470
+18
+1.8
+16 V ~
+23 V
400
400
0 A
0.2 A 0.45 A
-
Shutoff
47
Ballast
Output
380 VDC
360-400
VDC
25 Vpp
25 Vpp
(0.1)
(0.1) 250 W
410 V
Shutoff
Содержание EMP-S4
Страница 1: ...Service Manual Data Projector EMP S4 ...
Страница 13: ...Chapter 1 Product Specifications ...
Страница 25: ...1 13 EMP S4 SEIKO EPSON Revision B 1 5 External Views Figure 1 8 External Dimensions Unit mm ...
Страница 26: ...1 14 EMP S4 SEIKO EPSON Revision B Figure 1 9 External Dimensions Unit Inch ...
Страница 27: ...Chapter 2 Theory of Operation ...
Страница 49: ...Chapter 3 Troubleshooting ...
Страница 63: ...Chapter 4 Disassembly Assembly ...
Страница 97: ...Chapter 5 Appendix ...
Страница 102: ...5 6 EMP S4 SEIKO EPSON Revision B ...