4-48
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON
Revision:A
When installing the PS Ballast Assy., check the following.
• The
AC Cable is secured to the ditch of the Lower Case.
Figure 4-47.
• The AC Inlet is set so that the AC Cable come to the top.
• The tube part of the AC Inlet is not crossing over the Lamp Duct. (To prevent the
AC Cable from being caught between the IF Board Assy. and the Lamp Duct,
when the MA Board Assy. is installed.)(EMP-822/83 only)
Figure 4-48.
AC Cable
Lower Case
AC Inlet
AC Cable
Lamp Duct