3-19
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON
Revision:C
3.3.9 Control Panel’s Operation Check
Flowchart 3-11 Control Panel’s Operation Check
Start
O
K
N
G
N
G
2.
Replace
IS
board
Assy.
1.
Make
two
adjustments
referring
to
Ch5
Adjustment.
N
G
2.
Replace
Control
Panel.
1.
Does
pressing
[
Power
]
button
turn
the
power
on
/
off?
2.
Does
pressing
[
Menu
]
button
display
the
menu
window?
3.
Does
pressing
[
Source
Search
]
button
change
input
sources?
4
.
Does
pressing
[
Help
]
button
display
the
help
window?
5.
By
pressing
[
Enter
]
button,
is
the
selected
item
effective?
6.
By
pressing
the
keystone
buttons,
is
the
adjustment
effective?
7
.
By
pressing
[
ESC
]
button,
is
the
current
status
canceled?
8.
By
pressing
[
QuickSetup
]
button,
is
the
function
effective?
1.
Re
-
connect
MA
board
CN502
correctly.
3.
Replace
Optical
Engine
and
MAB
set.
N
G
N
G
If
replacing
IS
board
Assy,
make
the
same
adjustment
as
the
remedy
1
again.
If
it
does
not
work,
replace
Optical
Engine
and
MAB
set,
and
make
the
same
adjustment
again.
If
the
buttons
does
not
work
correctly,
apply
the
remedy
from
the
top
(1).
If
it
doesnot
work,
go
on
to
the
next
remedy.
For more information, refer to
4.3.4.1. "Removing the Control Panel E/Lamp Lid Detection Switch"
4.4.1 "Removing the Optical Engine and MAB (1) (MA Board Assy.)" (p. 20)
ing the Optical Engine and MAB (2) (Optical Engine)" (p. 42)
4.4.1.2. "Removing the SB Assy. IM*1
(IS Board Assy.*2)/IM Board Assy.*3 /CF Slot Assy.*3/USB Board Assy.*3" (p. 29)
Содержание EMP-1815
Страница 1: ...Service Manual Data Projector EMP 1825 EMP 1815 EMP 1810 ...
Страница 9: ...Chapter 1 Product Specifications ...
Страница 16: ...Chapter 2 Theory of Operation ...
Страница 23: ...Chapter 3 Troubleshooting ...
Страница 44: ...Chapter 4 Disassembly Assembly ...
Страница 105: ...Chapter 5 Adjustment ...
Страница 113: ...Chapter 6 Appendix ...