2.3 Temperature Control
The internal temperature of this projector is monitored by the sensors (the Lamp thermistor, L/
V thermistor) in order to protect the projector from internal overheat, which may cause unsafe
state or damage to the projector. The fans’ revolutions are controled according to the detected
temperature data. The fans’ revolutions are altered by changing the driving voltage based on
the detected data. In this way, the ventilation level is optimaized and the internal temperature is
kept stablized.
2.3.1 Sensors and Switches
The fans and sensors mounted in this product, and the routes of air flow are shown below.
Figure 2-5.
Part Name
Function
Intake Fan A/B
Take in fresh air from the intake duct (with Air Filter) located in the bottom of
the projector, and supply it to the Light Valves R/G/B.
P/S Fan
Ventilates the circuit boards of the PS Ballast Assy.
Lamp Fan
Ventilates the inside of the Lamp Unit.
PBS Fan
Ventilates the PBS (Polarizer) of the Optical Engine.
EX Fan
Exhausts the heated air generated inside the projector to the outside.
PBS Fan
EX Fan
TH Board
Lamp Fan
P/S Fan
Intake Fans
LV
Thermistor
Lamp (Heat source)
PS Ballast
(Heat source)
POP (Susceptible to heat)
Содержание EMP-1815
Страница 1: ...Service Manual Data Projector EMP 1825 EMP 1815 EMP 1810 ...
Страница 9: ...Chapter 1 Product Specifications ...
Страница 16: ...Chapter 2 Theory of Operation ...
Страница 23: ...Chapter 3 Troubleshooting ...
Страница 44: ...Chapter 4 Disassembly Assembly ...
Страница 105: ...Chapter 5 Adjustment ...
Страница 113: ...Chapter 6 Appendix ...