EH-TW3500/4500/5500
Disassembly and Assembly
CONFIDENTIAL
SEIKO EPSON
63
Revision A
3.3.6 RCF Board/RCR Board
1.
Remove the Lamp.
2.
Remove the Side Cover L/Side Cover R.
3.
Remove the Upper Case (assembly).
4.
Disconnect the RCR Cable from the connector on the MA board.
5.
Remove the screw and remove the RCR Board from the MA Plate.
6.
Remove the RCR Cable from the RCR Board.
Figure 3-11.
7.
Disconnect the RCF Cable from the connector on the MA board.
8.
Remove the screw and remove the Decoration Plate R from the Lower Case.
9.
Remove the RCF Board.
10. Remove the RCF Cable from the RCF Board.
Figure 3-12.
Standard Operation Time
7 Min.
MA Plate
RCR Cable
RCR Board
MA Board
C.C.P-TITE SCREW,3X8,F/ZN-3C
Lower Case
RCF Cable
RCF Board
Decoration Plate R
C.B.P-TITE SCREW,3X10,F/ZB-3C
MA Board
Содержание DREAMIO EH-TW2900
Страница 1: ...EH TW2900 3500 4400 4500 5500 Multimedia Projector SERVICE MANUAL CONFIDENTIAL ...
Страница 9: ...CONFIDENTIAL C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 16: ...CONFIDENTIAL C H A P T E R 2 TROUBLESHOOTING ...
Страница 46: ...CONFIDENTIAL C H A P T E R 3 DISASSEMBLYANDASSEMBLY ...
Страница 101: ...CONFIDENTIAL C H A P T E R 4 APPENDIX ...