EPSON AcuLaser C2800/C2800D/C3800/C3800D
Revision C
ADJUSTMENT
Adjustment Items
382
Confidential
5.1 Adjustment Items
The following table shows the adjustment items required after fixing or replacing certain parts (units).
*1 : Perform Color Registration Alignment (manual) if the misalignment in main-scanning direction is too severe to adjust by Color Registration Alignment (Auto).
Table 5-1. Adjustment Items
Parts
Timing
Adjustment Item
Procedure
Required Tools or Program
Reference
---
When the printer is transported without replacing
the cartridge(s).
When the color registration seems misaligned.
Color Registration Alignment (Auto)
Execute from the control panel.
---
Color Registration Alignment (Manual)
*1
Controller board After replacing the controller board with a new one.
Write USB ID
Execute from the special program. Special program
PWBA MCU
When replacing the PWBA MCU with a new one.
EEPROM Data Backup
EEPROM Data Restore
Execute from the special program. MCU Maintenance Program
When installing the PWBA MCU once used in other
printer.
MCU Initialize