AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
368
Confidential
4.
Release the protrusions on the left and right ends of the FEEDER ASSY UNIT OPT from the
FRAME ASSY OPT, and remove the FEEDER ASSY UNIT OPT.
Kmy03242EA
4)-1
4)-1
4)-2
4)-2
FEEDER ASSY UNIT OPT
ROLL ASSY TURN
1.
Remove the two E-rings that secure the shaft of the ROLL ASSY TURN.
2.
Remove the BEARING REGI (white) that secures the shaft of the ROLL ASSY TURN.
3.
Remove the BEARING REGI E (black) that secures the shaft of the ROLL ASSY TURN.
Install the white BEARING on the right and the black BEARING on the left as shown in the
figure.
4.
Temporarily slide the ROLL ASSY TURN toward left, pull out the right end of the ROLL ASSY
TURN from the CHUTE FDR OPT, and remove the ROLL ASSY TURN.
A
Kmy03243EA
1)
1)
4)
3) (
B
lack)
2) (White)
ROLL ASSY TURN