AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
331
Confidential
COVER SIDE IF
1.
Release the two tabs on the COVER SIDE IF, and remove the COVER SIDE IF.
A B
C
Kmy03008EA
1)-1
1)-1
1)-2
COVER SIDE IF
COVER SIDE R
As the FUSER UNIT remains at hazardous temperature after turning the power off, be
careful not to burn yourself.
1.
Release the lock on the right side of the FUSER UNIT.
2.
Remove the three screws (silver, self-tapping, 10 mm) that secure the COVER SIDE R to the main unit.
3.
Pull the COVER SIDE R so that it comes free from the two protrusions of the main unit.
4.
Release the two tabs on the back side and the two tabs on the front side of the COVER SIDE R, and
remove the COVER SIDE R from the main unit.
A B
C
Kmy03005EA
2)
2)
2)
3)
3)
4)-1
4)-1
4)-1
4)-1
4)-2
1)
COVER SIDE R
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...