AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
311
Confidential
FUSER UNIT
Be careful not to burn yourself as the FUSER section remains at high temperature after
turning the power off.
1.
Open the CHUTE DUP GATE.
2.
Rotate the levers on the left and right side of the FUSER UNIT as shown in the direction of the arrow,
and unlock the lock.
3.
Slide the FUSER UNIT toward front of the printer, release the connector and the guide pin from the
main unit, and remove the FUSER UNIT by lifting it straight up.
A
Kmy03046EA
1)
2)
2)
3)
FUSER UNIT
HOLDER ASSY WHEEL STAR
C H E C K
P O I N T
HOLDER ASSY WHEEL STAR on the other side can be removed in the same manner.
1.
Remove the screw (silver, brimmed, self-tapping, 8 mm) that secures the HOLDER ASSY WHEEL
STAR to the main unit.
2.
Remove the HOLDER ASSY WHEEL STAR from the main unit.
A
Kmy03048EA
1)
2)
HOLDER ASSY WHEEL STAR