AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
195
Confidential
2.
Disengage the guide pin on the right side of the TRANSFER UNIT from the cutout of the COVER
ASSY FRONT, remove the guide pin on the left side of the TRANSFER UNIT from the hole on the
COVER ASSY FRONT, and remove the TRANSFER UNIT.
Kmy03031EA
2)-1
2)-2
TRANSFER UNIT
CHUTE ASSY EXIT OUT
1.
Remove the two screws (silver, brimmed, self-tapping, 10 mm) that secure the CHUTE ASSY EXIT
OUT to the COVER ASSY FRONT.
2.
Remove the CHUTE ASSY EXIT OUT from the COVER ASSY FRONT.
A
Kmy03045EA
1)
1)
2)
CHUTE ASSY EXIT OUT