AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Engine-related Trouble FIP
113
Confidential
FIP 1-38 Replace Toner Black(K)
Possible parts that caused the error
Troubleshooting
FIP 1-39 Replace Transfer Unit
Possible parts that caused the error
Troubleshooting
IMAGING CARTRIDGE (K)
DISPENSER ASSY (K)
HARNESS ASSY LV TOP
PWBA MCU
Step
Check
Yes
No
1
Check after replacing the IMAGING
CARTRIDGE (K)
Replace the IMAGING CARTRIDGE (K) with
a new one.
Does the error still occur after the replacement?
Go to Step [2].
End of procedure
2
Check the connection of the DISPENSER
ASSY (K)
Check the connection state between
DISPENSER ASSY (K) and PWBA MCU.
Are P/J183 and P/J18 connected correctly?
Go to Step [3].
Reconnect P/J183
and P/J18
correctly.
3
Check the continuity of the HARNESS ASSY
LV TOP
Is the continuity between P/J18 <=> P/J183
normal?
Go to Step [4].
Replace the
HARNESS
ASSY LV TOP.
4
Check the power voltage supply to
DISPENSER ASSY (K)
1. Close the interlock switch (HARNESS
ASSY INTERLOCK) before performing
the following work.
2. Measure the voltage between PWBA
MCU ground <=> P/J18-B1PIN, B2PIN.
Is the power voltage (approx. +24 V) output?
Replace the
DISPENSER
ASSY (K).
Replace the
PWBA MCU.
TRANSFER UNIT
PWBA MCU
Step
Check
Yes
No
1
Check after replacing the TRANSFER UNIT
Replace the TRANSFER UNIT with a new one.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...