TROUBLESHOOTING
Engine-related Trouble FIP
109
Confidential
FIP 1-30 Service Req E900 (NV-RAM Error)
Possible parts that caused the error
Troubleshooting
FIP 1-31 Service Req E901 (Firmware Error)
Possible parts that caused the error
Troubleshooting
PWBA MCU
PWBA EEPROM XPRO
FUSER UNIT
TRANSFER UNIT
Step
Check
Yes
No
1
Check after turning the power OFF and ON
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check after reinstalling the PWBA MCU
Remove the PWBA MCU, and reinstall it
properly.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
PWBA MCU
Step
Check
Yes
No
1
Check after turning the power OFF and ON.
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check the firmware version
Is the firmware version latest?
Go to Step [3].
Update the
firmware.
3
Check after reinstalling the PWBA MCU
Remove the PWBA MCU, and reinstall it
properly.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...