Epsolar SS1024R Скачать руководство пользователя страница 16

12 

NOTE: Equipment damage! 

Over-charging and excessive gas precipitation may damage the 

battery plates and activate material shedding on them. Too high an 

equalizing charge or for too long may cause damage. Please       

                            carefully review the specific requirements of the battery used in the 

system. 

Certain  types  of  batteries  benefit  from  periodic  equalizing  charge,  which  can  stir  the 

electrolyte,  balance  battery  voltage  and  complete  chemical  reaction.  Equalizing  charge 

increases  the  battery  voltage,  higher  than  the  standard  complement  voltage,  which 

gasifies the battery electrolyte.

 

If  the  battery  is  being  over  discharged,  the  solar  controller  will  automatically  turn  to 

equalize  charging  stage,  and  the  equalize  stage  remain  120mins.

 

Equalize  charge  and 

boost charge are not carried out constantly in a full charge process to avoid too much gas 

precipitation or overheating of battery. 

4.3 LED 

Indicators

   

Charging Status LED indicator          Battery Status LED indicator 

 

 

 

 

 

 

Figure 4-2    LED indicators

 

Содержание SS1024R

Страница 1: ...duct This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please read this manual carefully before using the product and pay attention to t...

Страница 2: ......

Страница 3: ...input voltage 50V Nominal charge discharge current SS1024R 10A SS1524R 15A SS2024R 20A The controller will recognize the system rated voltage when start up If the battery voltage is lower than 18V it...

Страница 4: ...tions 4 3 1 General Installation 4 3 2 Mounting 5 3 3 Wiring 6 4 Operation 10 4 1 PWM Technology 10 4 2 Battery Charging Information 10 4 3 LED Indicators 12 4 4 Setting Operation 14 5 Protection Trou...

Страница 5: ...safe and Proper operation of the controller NOTE Indicates a procedure or function that is important for the safe and proper operation of the controller General Safety Information Read all of the ins...

Страница 6: ...function enhance the flexibility of street light system Gel Sealed and Flooded battery type option Adopt temperature compensation correct the charging and discharging parameters automatically and imp...

Страница 7: ...scharging 2 Charging status LED indicator An LED indicator that shows charging status and also indicates when battery voltage is higher than over voltage disconnect voltage 3 Battery status LED indica...

Страница 8: ...sive battery gasses may be present during charging Be certain there is sufficient ventilation to release the gasses Avoid direct sunlight and do not install in locations where water can enter the cont...

Страница 9: ...h flooded batteries Do not install in a confined area where battery gassed can accumulate Step 1 Choose Mounting Location Locate the controller on a vertical surface protected from direct sun high tem...

Страница 10: ...ecommended connection order has been provided for maximum safety during installation NOTE The controller is a common positive ground controller CAUTION Don t connect the loads with surge power exceedi...

Страница 11: ...ler start up for the first time When install fuse make sure that the biggest distance between the fuse holder and the positive terminal of battery is 150mm Do not insert a fuse at this time Confirm th...

Страница 12: ...should be fused separately The total load draw should not exceed the load rated current of controller Step 3 Solar wiring WARNING Risk of electric shock Exercise caution when handling solar wiring The...

Страница 13: ...Install Fuse Install a suitable fuse in each fuse holder in the following order 1 Battery circuit 2 Load circuit Step 6 Confirm power on When battery power is applied and the controller starts up the...

Страница 14: ...ns make some oxygen and hydrogen generated by chemical reaction chemically combined again and absorbed It can eliminate concentration polarization and ohm polarization naturally and reduce the interna...

Страница 15: ...lightly at the same time The purpose of Float stage is to offset the power consumption caused by self consumption and small loads in the whole system while maintaining full battery storage capacity In...

Страница 16: ...ance battery voltage and complete chemical reaction Equalizing charge increases the battery voltage higher than the standard complement voltage which gasifies the battery electrolyte If the battery is...

Страница 17: ...ORANGE ON when battery under voltage RED ON when battery over discharged Please refer to section 5 for troubleshooting Battery status LED indicator Table 4 2 Color Indicator Battery Status Green On s...

Страница 18: ...on indicator Table 4 4 Color LED digital tube System status Red H with slowly flashing Controller overheating 4 4 Setting Operation Dual timer function The default night length is 10 hours The control...

Страница 19: ...voltage and turn on the load after 10 minutes delay The load will be on for several hours which users set through LED digital tube The controller has dual timer function Please refer to table 4 5 Loa...

Страница 20: ...will be on for 3 hours after ten minutes delay since sunset 3 Load will be on for 4 hours after ten minutes delay since sunset 4 Load will be on for 5 hours after ten minutes delay since sunset 5 Load...

Страница 21: ...be on for 10 hours before sunrise 10 Load will be on for 11 hours before sunrise 11 Load will be on for 12 hours before sunrise 12 Load will be on for 13hours before sunrise 13 Load will be on for 14...

Страница 22: ...otected against load wiring short circuit After one automatic load reconnect attempt the fault must be cleared by reapply power or pressing the setting button PV Reverse Polarity Fully protection agai...

Страница 23: ...e falls on PV modules properly PV array disconnection Check that PV and battery wire connections are correct and tight Green charging LED indicator fast flashing Battery voltage higher than over volta...

Страница 24: ...troller will resume to work after 3s Digital tube displays H with red slowly flashing Too high temperature of controller When heat sink of the controller exceeds 85 the controller will automatically c...

Страница 25: ...e connections Check and confirm that LED digital tube is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective action Confirm that all the system...

Страница 26: ...of date and place of purchase To obtain rapid service under this warranty the returned products must include the model serial number and detailed reason for the failure the module type and size type...

Страница 27: ...t Voltage Drop 0 26V Discharge Circuit Voltage Drop 0 15V Self consumption 6mA Threshold Voltage Parameters Table7 2 Description Parameter NTTV Night Time Threshold Voltage 5V x2 24V DTTV Day Time Thr...

Страница 28: ...2V x2 24V 14 4V x2 24V 14 6V x2 24V Float Charging Voltage 13 8V x2 24V 13 8V x2 24V 13 8V x2 24V Boost Reconnect Charging Voltage 13 2V x2 24V 13 2V x2 24V 13 2V x2 24V Low Voltage Reconnect Voltage...

Страница 29: ...18 mm inches Mounting dimension 122 4 8 x 40 1 57 mm inches Mounting hole size 4 5 Terminal 6mm2 Net weight 0 15kg SS1524R SS2024R Mechanical Parameters Table 7 7 Mechanical Parameter Parameter Overal...

Страница 30: ...Figure1 SS1024R Dimensions 30 1 18 132 5 2 122 4 8 40 1 57 70 5 2 77 48 1 89 50 1 97 86 3 39 127 5 137 5 4 mm inches Figure2 SS1524R SS2024R Dimensions...

Страница 31: ......

Страница 32: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 010 82894112 82894962 Fax 010 82894882 E mail info epsolarpv com Website www epsolarpv com...

Отзывы: